Briggs & Stratton PRO4000 Operating Generator, Starting the Engine, Connecting Electrical Loads

Models: PRO4000

1 56
Download 56 pages 43.11 Kb
Page 9
Image 9

BSPP Generator

OPERATING THE

GENERATOR

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instruction steps in numerical order:

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Combustible debris, such as leaves, grass, brush, ect. can catch fire.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.

Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.

In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation.

2.Turn fuel valve to “On” position (Figure 4).

Figure 4 — Fuel Shut-off Valve

3.Make sure Idle Control switch is in “Off” position (Figure 5).

Figure 5 — Idle Control Switch

4.Follow start instructions given in engine owner’s manual.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.

This unit may be equipped with a low oil protection device. See engine manual.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.

DO NOT connect 3–phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload Generator”.

Stopping the Engine

1.Turn OFF and unplug ALL electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON.

2.Move idle control switch to “Off” position.

3.Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.

4.Move fuel valve to “Off” position.

5.Turn engine off according to instructions given in the engine manual.

9

Page 9
Image 9
Briggs & Stratton PRO4000 Operating Generator, Starting the Engine, Connecting Electrical Loads, Stopping the Engine

PRO4000 specifications

The Briggs & Stratton PRO4000 is a dependable and powerful generator designed to meet the needs of both residential and professional users. With a robust build and advanced technology, it offers an excellent solution for powering essential appliances during outages or for use at worksites.

One of the standout features of the PRO4000 is its impressive peak power output of 4000 watts, providing ample energy for multiple devices. This makes it an ideal choice for running refrigerators, sump pumps, or power tools simultaneously. The generator's continuous running wattage capacity ensures a steady power supply, allowing users to maintain their usual lifestyle even in emergencies.

The PRO4000 is equipped with a reliable Briggs & Stratton engine, renowned in the industry for its durability and efficiency. The engine employs OHV (Overhead Valve) technology, which enhances performance and fuel efficiency while reducing emissions. This means users can operate the generator longer on a single tank of fuel, making it economical and environmentally friendly.

Portability is another significant feature of the PRO4000. It is designed with a compact frame and comes with heavy-duty wheels and a foldable handle. This allows for easy transportation across various terrains, making it suitable for camping trips, construction sites, or any outdoor activities where temporary power is required.

Safety is a priority with the PRO4000. It integrates advanced safety features like overload protection that automatically shuts off the generator to prevent damage, ensuring it runs smoothly and safely. The generator also incorporates a low oil shutdown feature that protects the engine from damage by shutting down when oil levels are too low.

User-friendly controls make the PRO4000 accessible for anyone to operate. The generator features clearly marked outlets for easy connection of devices, and an easy-to-read fuel gauge allows users to monitor fuel levels without opening the tank.

In summary, the Briggs & Stratton PRO4000 stands out with its powerful performance, reliable engine technology, portability, and safety features. Whether for home use during power outages or for commercial applications, the PRO4000 offers the versatility and reliability that users can depend on. It is an investment that ensures peace of mind and preparedness for whatever challenges come your way.