3. PREPARE CUSTOM HOOD
!WARNING
When building a custom hood, always follow all applicable construction codes and standards. The custom hood must be positively secured to wall studs or other wooden framework behind the drywall. Make sure it is capable of supporting its own weight and the weight of the power pack. Failure to do so may cause personal injury or damage to countertop or cooktop.
The custom hood must be constructed to fit the shape and total weight of the EC62 power pack model. The recommended minimum thickness for the custom hood base is 5/8”. If an optional custom hood liner will be installed, we recommend the sides and front of the custom hood to be 3/4” thick. If the optional custom hood liner will not be installed, the custom hood sides and front thickness are at the installer’s discretion. See chart and illustration for details.
POWER PACK | TOTAL |
TYPES | WEIGHT |
|
|
SINGLE BLOWER | 33 LB |
|
|
DUAL BLOWER | 45 LB |
|
|
SINGLE BLOWER POWER PACK
| TOP VIEW |
|
|
7/8” |
| 5/8” |
|
| 1¾” |
|
|
| 13 5/16” |
|
|
|
|
| 10½” |
|
|
| 5/8” |
1¾” |
| 3 ³/16” |
|
|
| 10 15/16” | |
| 9¾” | 10 1/8” | |
2 15/16” |
|
| 3 ³/16” |
| 26 5/8” | 11/16” | 13¼” |
| 28 1/8” |
| 14¾” |
HK0104A | BACK VIEW |
| SIDE VIEW |
DUAL BLOWER POWER PACK
NOTE: The dual blower model has the same dimensions than the single blower model, but does not have a horizontal discharge. Refer to single blower power pack illustration for back and side views, and discard horizontal discharge measurements.
| 13 5/16” |
ø10” | 1¾” |
| 7/8” |
| 5¼” |
HK0114A | TOP VIEW |
| - 5 - |