Broan EI5936SS Plan The Installation, INSTALL THE DUCTWORK Ducted Hoods Only, Install The Wiring

Models: EI5936SS

1 32
Download 32 pages 11.48 Kb
Page 2
Image 2
PLAN THE INSTALLATION

MODEL EI5936SS

PLAN THE INSTALLATION

ROOF CAP

 

 

 

6” ROUND

 

 

DUCT

 

DECORATIVE

6” ROUND

 

FLUES

EAVE

ELBOWS

 

VENT

 

 

HOOD

DUCT CENTER LINE

 

(1” to rear of hood centerline)

 

HOOD

 

 

CENTER

 

24” TO 36” ABOVE

LINE

 

 

 

COOKING SUFACE

 

 

The minimum hood distance above cooktop MUST NOT BE LESS than 24”.

A maximum of 36” above cooktop is recommended for best capture of cooking impurities.

Distances over 36” are at the installer and users discretion; providing that the ceiling height permits.

INSTALL THE DUCTWORK (Ducted Hoods Only)

1.Decide where the ductwork will run between the hood and the outside.

2.A straight, short duct run will allow the hood to perform most efficiently.

3.Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.

4.Install wall cap or roof cap. Connect round metal ductwork to cap and work back towards the hood location. Use duct tape to seal the joints between ductwork sections.

Page 2

INSTALL THE CEILING SUPPORT

 

8” MINIMUM

 

FRONT

8½”

 

ON CENTER

 

 

HOOD

 

HOOD

 

CENTERLINE

CENTERLINE

 

 

 

 

 

DUCT

 

 

CENTERLINE

 

 

OFFSET 1” TO

 

 

REAR OF HOOD

1.Construct wood framing that is flush with interior surface of the ceiling joists.

NOTE

Hood distance above cooktop is: Minimum 24”, Maximum 36”. 9-10 ft. ceilings may require Flue Extension Model FXNE59SS, depending on installation height (purchase separately). Discard the upper and lower flues, mounting frame, and trim strips supplied with your hood and replace them with Flue Extension Model FXNE59SS.

2.Finish opening to match surrounding ceiling carefully marking framing location.

INSTALL THE WIRING

 

HOUSE WIRING

 

 

IN THIS AREA

 

 

FRONT

 

 

 

5”

HOOD

 

3½”

3½”

 

CENTERLINE

 

 

HOOD

 

2”

 

CENTERLINE

 

 

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

Position the electrical (house wiring) within the space covered by the decorative flue and where it will not interfere with the round duct. Make sure the length of the house wiring is a minimum of 5 feet. It may be shortened after hood is installed at correct height and electrical connection is made.