Broan EI5936SS INSTALL THE HOOD Ducted hoods only - Steps 1, Frame Length “L”, Ceiling, Above

Models: EI5936SS

1 32
Download 32 pages 11.48 Kb
Page 4
Image 4
INSTALL THE HOOD (Ducted hoods only - Steps 1 & 2)

MODEL EI5936SS

Page 4

INSTALL THE HOOD (Ducted hoods only - Steps 1 & 2)

NON-DUCTED HOOD INSTALLATION - SKIP TO STEP 3.

LENGTH

“L”

1.Determine length “L” of frame assembly based upon desired installation height. (See chart below.) To adjust frame assembly height, remove (8) screws, slide upper frame assembly to required height, replace screws and tighten securely.

Desired Hood Distance (Above 36" High Cooktop)

 

24"

25"

26"

27"

28"

29"

30"

31"

32"

33"

34"

35"

36"

Ceiling

 

 

 

 

 

Frame Length “L”

 

 

 

 

 

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 Feet

* 20-5/8"

19-5/8”

18-5/8”

17-5/8”

16-5/8”

15-5/8”

 

 

 

 

 

 

 

9 Feet

 

 

 

 

 

 

 

 

 

* 23-5/8”

* 22-5/8”

* 21-5/8”

* 20-5/8”

9 Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

with

32-5/8"

31-5/8"

30-5/8"

29-5/8"

28-5/8"

27-5/8"

26-5/8"

 

 

 

 

 

 

FXNE59SS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

with

44-5/8"

43-5/8"

42-5/8"

41-5/8"

40-5/8"

39-5/8"

38-5/8"

37-5/8"

36-5/8"

35-5/8"

34-5/8"

33-5/8"

32-5/8"

FXNE59SS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Non-duct recirculation louvers will be exposed in ducted configuration

CEILING
MATERIAL

IS INSTALLED.

CEILING

FRAMING
ABOVE -
SHOWN
AS DOTTED
LINES.

2.Align frame assembly to ceiling framing, and attach to ceiling framing with (6) 4mm x 50mm screws. Tighten securely, making sure that the upper frame bracket is tight against the ceiling.

DUCTED HOOD INSTALLATION - SKIP TO STEP 9.

Page 4
Image 4
Broan EI5936SS INSTALL THE HOOD Ducted hoods only - Steps 1, Non-Ducted Hood Installation - Skip To Step, Length, Ceiling