MAKE-UP AIR DAMPER

MODELS EW5630SS • EW5636SS

To replace a fuse (by qualified person(s):

1.Disconnect power at service entrance.

2.Remove decorative flues.

3.Remove control cover.

4.Remove and inspect fuse.

MAKE-UP AIR DAMPER

The hood is compatible with Broan Make-Up Air Damper Model MD6T or Model MD8T (optional). Purchase separately.

MAKE-UP AIR DAMPER

MAKE UP DAMPER CONNECTION

 

(switched low voltage)

 

20 GAUGE BELL WIRE FOR LOW

 

VOLTAGE CONNECTION ON

 

TOP OF HOOD

 

24V

 

 

TRANSFORMER

DRY CONTACT

(INCLUDED)

 

 

TERMINAL

 

 

GRD

HOOD

BUSHING

 

 

FOR LOW

120 VAC

 

VOLTAGE

60 HZ

 

CONNECTION

Make the connection to the Make-Up Air Damper with low voltage wiring, as shown. See Make-Up Air Damper instructions for additional information.

REMOTE CONTROL

The hood is compatible with Broan Radio Frequency (RF) Remote Control Model BCR1 (optional). Purchase separately.

To link the BCR1 remote control with the hood, press and hold the LIGH T button for 3-seconds.

The blue LED indicators will turn on and off in succession to indicate the hood is in RF linking mode. When in the linking mode, press any key on the RF remote. An audible beep will be heard at the hood, and the hood LED’s will stop blinking if a successful link is accomplished. If the remote control did not successfully link with the hood, the linking mode will be deactivated after 12 seconds, and the LED’s will stop the sequential blinking. Refer to the BCR1 instructions for additional information.

CLEANING & MAINTENANCE

For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild detergent solution on stainless and painted surfaces.

Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty.

Clean the non-duct recirculating filter surfaces frequently with a damp cloth and a mild detergent. DO NOT immerse filters in water or put in dishwasher. Change the non-duct recirculating filters every 6 months. For replacement non-duct recirculating filters - purchase S99010365 or Model FILTERE56.

The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the blower assembly with an exact service replacement.

Page 8

LIGHT BULBS

 

SUCTION

 

CUP TOOL

HALOGEN

(1)

PUSH IN

BULB

 

(2)

 

ROTATE

 

CLOCKWISE

 

WARNING

Bulbs may be hot. Always allow bulbs to cool down before removing them.

Use (2) Halogen Bulbs (included with hood) - 120 V, 35 W, shielded halogen bulbs - MR16 with GU10 base.

NOTE

Suction Cup Tool (included with hood) can be used to install and remove light bulbs. Align pins on bulb with large diameter opening on socket, then push bulb in towards hood and rotate clockwise until firmly seated. The position of the bulb socket (depth) is adjustable and may require adjustment when: a) certain brands of bulbs are difficult to install. b) the bulb protrudes too far below the light panel.

LAMP SOCKET

BRACKET

LIGHT

SCREWS

PANEL

To change the depth of bulb sockets:

-Remove 2 screws on light panel – set screws aside

-Remove Light Panel.

-Loosen 2 Screws holding Lamp Socket Bracket to Light Panel.

-Adjust socket/bracket to desired depth.

-Re-tighten screws securely.

-Re-attach light panel with 2 screws that were previously set aside.