MODELS EW5630SS • EW5636SS

Page 2

MEASURE THE INSTALLATION

 

ROOF CAP

 

ROUND ELBOW

6” ROUND DUCT

WALL CAP

 

DECORATIVE FLUE

HOOD MOUNTING

 

3¾” FROM WALL

BRACKET

 

TO CENTER LINE

 

OF DUCT

 

DECORATIVE FLUE

15 7/8TO CENTER

 

OF UPPER BRACKET

HOOD

HOLES

3½”

 

 

2” TO CENTER

24” TO 36” ABOVE

OF LOWER HOOD

CHASIS HOLES

COOKING SURFACE

 

The minimum hood distance above cooktop MUST NOT BE LESS than 24”.

A maximum of 36” above cooktop is recommended for best capture of cooking impurities.

Distances over 36” are at the installer and users discretion; providing that the ceiling height permits.

INSTALL THE DUCTWORK (Ducted Hoods Only)

1.Decide where the ductwork will run between the hood and the outside.

2.A straight, short duct run will allow the hood to perform most efficiently.

3.Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.

4.Install wall cap or roof cap. Connect round metal ductwork to cap and work back towards the hood location. Use duct tape to seal the joints between ductwork sections.

PREPARE THE HOOD

Unpack hood and check contents.You should receive:

1 - Hood Assembly

1 - Glass Canopy

1 - Decorative Flue Assembly (consisting of upper and lower flue)

1 - Upper Flue Mounting Bracket

1 - Aluminum Grease Filter (installed on hood)

2 - 35W MR16 GU10 Halogen Lamps (installed on hood)

1 - Parts Bag containing:

6 - Mounting Screws (4mm x 38mm Cross Recessed Pan Head) 2 - Mounting Screws (4mm x 12mm Cross Recessed Pan Head) 4 - Mounting Screws (.188” x .250” Cross Recessed Flat Head) 1 - Suction Cup Tool

1 - Installation Manual

 

2 MOUNTING

 

SCREWS

UPPER

(4mm x 12mm

Cross Recessed

FLUE MOUNTING

Pan Head)

BRACKET

 

 

DECORATIVE

 

FLUE

 

ASSEMBLY

4 MOUNTING

 

SCREWS

 

(.188” x .250”

 

Cross Recessed

 

Flat Head)

 

 

6 MOUNTING

 

SCREWS

 

(4mm x 38mm

 

Cross Recessed

 

Pan Head)

 

GLASS

 

CANOPY

BULB

HOOD

ASSEMBLY

SUCTION

 

CUP TOOL

 

Page 2
Image 2
Broan EW5636SS, EW5630SS manual Measure the Installation, Install the Ductwork Ducted Hoods Only, Prepare the Hood