Broan QT230SS Wiring Connections, Lamp Installing Or Replacement, Maintenance, Filters, Cleaning

Models: QT230SS

1 12
Download 12 pages 40.59 Kb
Page 4
Image 4
WIRING CONNECTIONS

WIRING CONNECTIONS

All wiring connections must comply with local codes and the unit must be properly grounded.

1.Make sure box connector is secure.

2.Refer to FIGURE 8. Make wiring connections.

3.Replace electrical box cover and secure with screw.

LAMP INSTALLING

OR REPLACEMENT

1.Depress sides of light diffuser until tabs of diffuser disengage from slots in hood. Remove diffuser.

2.Install (2) 40 watt maximum, Type A-15 appliance bulbs.

3.Replace difuser in hood by depressing sides and engaging tabs in slots in hood.

FILTER INSTALLATION

AND REPLACEMENT

1.For ducted operation, install the aluminum mesh filter. For non- duct operation, install the non-ducted filter (Model BPQTF, sold separately).

2.Refer to FIGURE 9. The filter slides into channels at the back of the hood, on either side of the fan compartment, and snaps under the spring clips near the front of the fan compartment.

MAINTENANCE

FILTERS

IMPORTANT: The aluminum filter should be removed once monthly and washed in hot detergent water. Rinse in clear, warm water and shake off excess moisture before replacing. The filter may also be cleaned in your dishwasher.

IN A NON-DUCTED INSTALLATION: Replace filter every 3-6 months as needed.

CLEANING

The hood should be wiped off occasionally both inside and outside using warm water, mild dish detergent and a soft cloth. Never use scouring powders, steel wool pads or any other abrasive cleaners which will destroy the hood’s finish.

HOOD WIRING

WHT

BLK

GREEN GROUND SCREW

WHT

SUPPLY

 

BLK

WIRING

GREEN

 

OR BARE

 

(GROUND)

 

FIGURE 8

FIGURE 9