Broan WC26I manual Install Mounting Bracket, DUCTED and NON-DUCTED HOODS

Models: WC26I

1 44
Download 44 pages 55.03 Kb
Page 9
Image 9
INSTALL MOUNTING

INSTALL MOUNTING

BRACKET

DUCTED and NON-DUCTED HOODS

1.Construct wood wall framing that is flush with interior surface of wall studs. Fig. 7. Make sure:

a)the framing is centered over installation location.

b)the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown.

2.After wall surface is finished, secure the mounting bracket to framing with (2) 4.8 x 38mm mounting screws. See chart below for mounting bracket location.

FRAMING BEHIND

WOOD CROSS

 

SUPPORT

 

WOOD CROSS

DRYWALL

SUPPORT BEHIND

 

DRYWALL

 

FIG. 7

 

CEILING HEIGHT

 

 

HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a)

 

 

 

 

22”

 

23”

 

24”

 

25”

 

26”

 

27”

 

28”

 

 

 

 

 

 

 

 

 

 

 

MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-FOOT

41-1/4”

 

42-1/4”

 

43-1/4”

44-1/4”

 

 

 

 

 

 

 

 

9-FOOT

41-1/4”

 

42-1/4”

 

43-1/4”

44-1/4”

 

45-1/4”

 

46-1/4”

 

47-1/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10- FOOT (see note b)

41-1/4”

 

42-1/4”

 

43-1/4”

44-1/4”

 

45-1/4”

 

46-1/4”

 

47-1/4”

 

Notes:

a.Minimum hood distance above cook top must not be less than 22”.

A maximun of 28” above cook top is highly recommended for best capture of cooking impurities.

Distances over 28” are at the installer and user’s discretion; and if ceiling height and flue length permits.

b.Requires optional 10’ flue extension, ducted model AEWC26xB or non-ducted model AEWC26xBN.