4

 

 

 

 

In this chapter

The updates in this chapter are for the Brocade VDX 6710-54 Hardware Reference Manual, part number: 53-10002390-04, published March 2012.

Chapter 4, Brocade VDX 6710-54 Operation . . . . . . . . . . . . . . . . . . . . . . . . 29

Chapter 5, FRU Removal and Replacement Procedures . . . . . . . . . . . . . . . 29

Chapter 4, Brocade VDX 6710-54 Operation

Under the heading “Brocade VDX 6710-54 management” on page 29, replace Table 5 with the following information.

TABLE 5 Management options for the Brocade VDX 6710-54

Management tool

Out-of-band support

In-band support

 

 

 

Command line interface (CLI)

Ethernet or serial

In standalone mode

Up to two admin sessions and four user sessions simultaneously.

(console port)

only. Not available in

For more information, refer to the Network OS Administrator’s

connection

VCS mode.

Guide and the Brocade Network OS Command Reference.

 

 

 

 

 

Standard SNMP applications

Ethernet or serial

N/A

For information, refer to the Network OS Administrator’s Guide

(console port)

 

and the Brocade Network OS MIB Reference.

connection

 

 

 

 

Brocade Network Advisor

Ethernet (preferred)

N/A

For information, refer to the Brocade Network Advisor SAN+IP

or serial (console

 

User Manual.

port) connection

 

 

 

 

Chapter 5, FRU Removal and Replacement Procedures

Under the heading “Replacing the power supply and fan assembly” on page 36, add a step after step 5 and before the paragraph that says “"You can display the power supply and fan assembly status using the following commands from the CLI:”

Step 6. If you have changed the airflow direction in the chassis by installing two FRUs with a new airflow direction, you must run the command chassis fan airflow-direction[port-side-direction], where the [port-side-direction] operands are either port-side-intakeor port-side-exhaust, depending on which direction the airflow is directed.

switch# chassis fan airflow-direction port-side-exhaust Previous configuration : port-side-intake

Current configuration : port-side-exhaust

System fan airflow-direction changes will be effective after reboot!!