System status LEDs |
| 3 | |
| Controller status (primary system) | ||
|
|
|
|
| System status 1 LED | System status 2 LED | Event |
|
|
|
|
| Off | Off | Power off |
|
|
|
|
| Green Solid | Off | No Redundancy Feature Enabled |
|
|
|
|
| Green Solid | Green Solid | Redundancy Feature Enabled |
|
|
| Actively Adopting Access Points |
|
|
|
|
| Green Solid | Amber Blinking | No License to adopt Access Points |
|
|
| or |
|
|
| No Country Code configured on the controller |
|
|
| or |
|
|
| License and Country Code configured, but no |
|
|
| APs adopted |
|
| ||
| Controller status (redundant system) | ||
|
|
|
|
| System status 1 LED | System status 2 LED | Event |
|
|
|
|
| Off | Off | Power off |
|
|
|
|
| Green Solid | Off | No Redundancy Feature Enabled |
|
|
|
|
| Green Blinking | Green Solid | Redundant System failed over and |
|
|
| adopting ports |
|
|
| |
| Green Blinking | Alternating Green Blinking Redundant System not failed over. | |
|
| & Amber Blinking |
|
|
|
|
|
| Green Solid | Amber Blinking | No License to adopt Access Points |
|
|
| or |
No Country Code configured on the controller
or
License and Country Code configured, but no APs adopted
Brocade Mobility RFS6000 Controller Installation Guide | 9 |
|