GAS CONVERSION TO NATURAL GAS
1.R3B Grills: Remove cooking grids, briquets and bri- quet rack from grill.
2.Blue Flame Burner: Remove blue flame burner shield and blue flame burner from grill (one (1)
Infrared Burner: Remove ignitor wire, lugs and infrared burner from grill (one (1)
3.Remove LP burner orifices marked 1.25 mm for R3B. Remove LP burner orifice marked 1.3 mm for R3. See
Figure 17.
|
| Figure 17 | ||
| 4. | Install natural gas burner orifice marked 49 into each | ||
|
| orifice fitting. Apply pipe compound to threads on ori- | ||
|
| fices prior to installation. |
| |
| 5. | Blue Flame Burner: Place burner shield and burn- | ||
|
| ers into grill and insert burner tubes over orifice fit- | ||
|
| tings. Secure each burner | with one (1) | |
|
| 3/4 phillips screw from Step 2. | ||
|
| Infrared Burner: Place infrared burners, ignitor, and | ||
|
| lugs into grill and insert burner tubes over orifice fit- | ||
|
| tings. Secure each burner with one (1) | ||
|
| lips screw from step 2. |
| |
| 6. | Grasp valve knobs and remove from valves. | ||
| 7. | The low input adjustment screws are located inside | ||
|
| the two valve stems. Use a small screwdriver to turn | ||
|
| each adjustment screw clockwise 1/4 turn (90 degrees). | ||
R3B |
| When valves are in the "OFF" position, the slot in the | ||
| adjustment screw should be vertical. See Figure 18. | |||
| ADJUSTMENT SCREW | ADJUSTMENT SCREW | ||
|
| NAT | LPG | |
|
| Figure 18 | ||
| 8. | Remove the hose and regulator from the gas connection | ||
|
| on grill with adjustable wrench. | ||
| 9. | Connect the grill to the natural gas supply. | ||
|
| Attention: Before lighting your grill check all gas | ||
|
| connections including the adjustment screws in valve | ||
|
| stems for gas leaks with a soapy water mixture. | ||
|
| Caution: Do not use the grill if a gas leak is detect- | ||
|
| ed until gas leak is corrected. If a gas leak can not be | ||
|
| stopped, do not use grill. You must contact a qualified | ||
|
| repair person. |
| |
R3 | 10. | Push valve knobs onto valves. | ||
11. | Apply the completed conversion label adjacent to the | |||
Figure 16 | ||||
| rating plate label on the grill. |
| ||
|
| Page 17 |