Broilmaster R3-1, R3N-1, R3BN-1, R3B-1 owner manual Gas Conversion To Natural Gas

Models: R3B-1 R3BN-1 R3-1 R3N-1

1 32
Download 32 pages 17.57 Kb
Page 17
Image 17
GAS CONVERSION TO NATURAL GAS

GAS CONVERSION TO NATURAL GAS

1.R3B Grills: Remove cooking grids, briquets and bri- quet rack from grill.

2.Blue Flame Burner: Remove blue flame burner shield and blue flame burner from grill (one (1) 1/4-20 x 3/4 phillips screw for burner). See Figure 16.

Infrared Burner: Remove ignitor wire, lugs and infrared burner from grill (one (1) 1/4-20 x 3/4 phillips screw for each burner). See Figure 16.

3.Remove LP burner orifices marked 1.25 mm for R3B. Remove LP burner orifice marked 1.3 mm for R3. See

Figure 17.

 

 

Figure 17

 

4.

Install natural gas burner orifice marked 49 into each

 

 

orifice fitting. Apply pipe compound to threads on ori-

 

 

fices prior to installation.

 

 

5.

Blue Flame Burner: Place burner shield and burn-

 

 

ers into grill and insert burner tubes over orifice fit-

 

 

tings. Secure each burner

with one (1) 1/4-20 x

 

 

3/4 phillips screw from Step 2.

 

 

Infrared Burner: Place infrared burners, ignitor, and

 

 

lugs into grill and insert burner tubes over orifice fit-

 

 

tings. Secure each burner with one (1) 1/4-20 x 3/4 phil-

 

 

lips screw from step 2.

 

 

6.

Grasp valve knobs and remove from valves.

 

7.

The low input adjustment screws are located inside

 

 

the two valve stems. Use a small screwdriver to turn

 

 

each adjustment screw clockwise 1/4 turn (90 degrees).

R3B

 

When valves are in the "OFF" position, the slot in the

 

adjustment screw should be vertical. See Figure 18.

 

ADJUSTMENT SCREW

ADJUSTMENT SCREW

 

 

NAT

LPG

 

 

Figure 18

 

8.

Remove the hose and regulator from the gas connection

 

 

on grill with adjustable wrench.

 

9.

Connect the grill to the natural gas supply.

 

 

Attention: Before lighting your grill check all gas

 

 

connections including the adjustment screws in valve

 

 

stems for gas leaks with a soapy water mixture.

 

 

Caution: Do not use the grill if a gas leak is detect-

 

 

ed until gas leak is corrected. If a gas leak can not be

 

 

stopped, do not use grill. You must contact a qualified

 

 

repair person.

 

R3

10.

Push valve knobs onto valves.

11.

Apply the completed conversion label adjacent to the

Figure 16

 

rating plate label on the grill.

 

B101278-2-1008

 

 

Page 17

Page 17
Image 17
Broilmaster R3-1, R3N-1, R3BN-1, R3B-1 owner manual Gas Conversion To Natural Gas