Table 1 – Opening Dimensions - In. (mm)

 

 

 

 

 

 

FURNACE

APPLICATION

PLENUM OPENING

FLOOR OPENING

(APPROVED FACTORY SUPPLIED CASED COILS AND

CASING

 

 

 

 

COIL BOX: CD5, CKR, CAPVP, CARVP, CAPMP, CARMP,

 

 

 

 

WIDTH

A

B

C

D

CNPVP, CNRVP, AND KCAKC)

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible

16

24--- 1/8

16--- 5/8

24--- 3/4

 

Flooring (KGASB subbase not required)

(406)

(613)

(422)

(629)

 

 

 

 

 

 

 

Downflow Applications on Noncombustible Flooring (KGASB

15--- 7/8

19

16--- 1/2

19--- 5/8

 

subbase not required)

(403)

(483)

(419)

(498)

17 ½

 

 

 

 

 

Downflow applications on combustible flooring (KGASB sub-

15--- 1/8

19

16--- 3/4

20--- 3/8

(445)

base required)

(384)

(483)

(425)

(518)

 

Downflow Applications on Combustible Flooring with Factory

15--- 1/2

19

16--- 1/2

20

 

supplied cased coil or Factory supplied coil box (KGASB

 

(394)

(483)

(419)

(508)

 

subbase not required)

 

 

 

 

 

 

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible

19--- 1/2

24--- 1/8

20--- 1/8

24--- 3/4

 

Flooring (KGASB subbase not required)

(495)

(613)

(511)

(629)

 

 

 

 

 

 

 

Downflow Applications on Noncombustible Flooring (KGASB

19--- 3/8

19

20

19--- 5/8

21

subbase not required)

(492)

(483)

(508)

(498)

Downflow applications on combustible flooring (KGASB sub-

18--- 5/8

19

20--- 1/4

20--- 3/8

(533)

base required)

(473)

(483)

(514)

(518)

 

 

 

 

 

 

 

 

Downflow Applications on Combustible Flooring with Factory

19

19

20

20

 

supplied cased coil or Factory supplied coil box (KGASB

 

(483)

(483)

(508)

(508)

 

subbase not required)

 

 

 

 

 

 

 

 

 

 

 

 

Upflow Applications on Combustible or Noncombustible

23

24--- 1/8

23--- 5/8

24--- 3/4

 

Flooring (KGASB subbase not required)

(584)

(613)

(600)

(629)

 

 

 

 

 

 

 

Downflow Applications on Noncombustible Flooring (KGASB

22--- 7/8

19

23--- 1/2

19--- 5/8

24---1/2

subbase not required)

(581)

(483)

(597)

(498)

 

 

 

 

 

Downflow applications on Combustible flooring (KGASB

22--- 1/8

19

23--- 3/4

20--- 3/8

(622)

subbase required)

(562)

(483)

(603)

(518)

 

 

 

 

 

 

 

 

Downflow Applications on Combustible Flooring with Factory

22--- 1/2

19

23--- 1/2

20

 

supplied cased coil or Factory supplied coil box (KGASB

 

(572)

(483)

(597)

(508)

 

subbase not required)

 

 

 

 

 

 

 

 

 

 

 

355CAV

AIR DUCTS

General Requirements

The duct system should be designed and sized according to accepted national standards such as those published by: Air Conditioning Contractors Association (ACCA), Sheet Metal and Air Conditioning Contractors National Association (SMACNA) or American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) or consult The Air Systems Design Guidelines reference tables available from your local distributor. The duct system should be sized to handle the required system design CFM at the design static pressure.

When a furnace is installed so that the supply ducts carry air circulated by the furnace to areas outside the space containing the furnace, the return air must also be handled by a duct(s) sealed to the furnace casing and terminating outside the space containing the furnace.

Secure ductwork with proper fasteners for type of ductwork used. Seal supply- and return-duct connections to furnace with code approved tape or duct sealer.

Flexible connections should be used between ductwork and furnace to prevent transmission of vibration. Ductwork passing through unconditioned space should be insulated to enhance system performance. When air conditioning is used, a vapor barrier is recommended.

Maintain a 1-in. (25 mm) clearance from combustible materials to supply air ductwork for a distance of 36 in. (914 mm) horizontally from the furnace. See NFPA 90B or local code for further requirements.

For a furnace not equipped with a cooling coil, the outlet duct shall be provided with a removable access panel. This opening shall be accessible when the furnace is installed and shall be of such a size that the heat exchanger can be viewed for possible openings using light assistance or a probe can be inserted for sampling the air stream. The cover attachment shall prevent leaks.

Ductwork Acoustical Treatment

Metal duct systems that do not have a 90 degree elbow and 10 ft. (3M) of main duct to the first branch take-off may require internal acoustical lining. As an alternative, fibrous ductwork may be used if constructed and installed in accordance with the latest edition of SMACNA construction standard on fibrous glass ducts. Both acoustical lining and fibrous ductwork shall comply with NFPA 90B as tested by UL Standard 181 for Class 1 Rigid air ducts.

Supply Air Connections

Upflow Furnaces

Connect supply-air duct to 3/4-in. (19 mm)flange on furnace supply-air outlet. The supply-air duct attachment must ONLY be connected to furnace supply-/outlet-air duct flanges or air conditioning coil casing (when used). DO NOT cut main furnace casing to attach supply side air duct, humidifier, or other accessories. All accessories MUST be connected external to furnace main casing.

Downflow Furnaces

Connect supply-air duct to supply-air opening on furnace. The supply-air duct attachment must ONLY be connected to furnace supply/outlet or air conditioning coil casing (when used) when installed on non-combustible material When installed on combustible material, supply air duct attachment must ONLY be connected to an accessory subbase or factory approved air conditioning coil casing. DO NOT cut main furnace casing to attach supply side air duct, humidifier, or other accessories. All accessories MUST be connected external to furnace main casing. Supply air opening duct flanges must be modified per Fig. 22.

Horizontal Furnaces

Connect supply-air duct to supply-air opening on furnace. The supply-air duct attachment must ONLY be connected to furnace supply/outlet or air conditioning coil casing (when used). DO NOT cut main furnace casing to attach supply side air duct,

21

Page 21
Image 21
Bryant 355CAV installation instructions AIR Ducts

355CAV specifications

The Bryant 355CAV is a state-of-the-art automated vertical machining center designed to enhance precision and efficiency in the manufacturing sector. Renowned for its robust construction, this machine is engineered to handle a broad spectrum of machining tasks, making it suitable for both small and large-scale production environments.

One of the standout features of the Bryant 355CAV is its advanced CNC control system, which provides users with exceptional ease of use. The intuitive user interface allows operators to program complex machining operations with minimal effort, significantly reducing setup times. The machine's high-speed spindle achieves impressive rotational speeds, which allows for quick material removal, ultimately optimizing productivity and throughput.

The Bryant 355CAV exhibits superior rigidity and stability due to its solid cast iron frame and carefully designed structural components. This construction minimizes vibrations during machining, ensuring that even the most intricate parts are produced with high accuracy. The machine's precision ground linear guideways further enhance its performance by providing smooth motion and high load capacity.

Equipped with a large work envelope, the Bryant 355CAV enables manufacturers to accommodate various part sizes and geometries. Additionally, its automatic tool changers can hold a variety of tools, thus facilitating quick transitions between different machining operations without requiring manual intervention. This flexibility is essential for meeting the diverse needs of modern manufacturing.

Another notable characteristic of the Bryant 355CAV is its energy-efficient design. It integrates modern technologies aimed at reducing power consumption while maintaining optimum performance. This environmentally conscious approach not only cuts operational costs but also aligns with the growing demand for sustainable manufacturing practices.

Moreover, the Bryant 355CAV features advanced monitoring capabilities, allowing operators to track machine performance in real time. Data analytics from these systems can be utilized to improve operational efficiency, reduce downtime, and enhance predictive maintenance protocols.

In summary, the Bryant 355CAV is a versatile, high-performance machining center that showcases cutting-edge features and technologies. Its combination of user-friendly controls, sturdy construction, energy efficiency, and advanced monitoring positions it as a vital asset for manufacturers aiming to elevate their productivity and precision in an increasingly competitive landscape.