Bryant 524J manual Model Number Nomenclature, Serial Number Nomenclature, Foam Block Location

Models: 524J

1 36
Download 36 pages 19.5 Kb
Page 9
Image 9
Fig. 3 - Model Number Nomenclature

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

5 2 4 J E 2 5 A 0 0 0 A 2 0 A A A

_____________

____

Model Type

524J = Bryant Fan Coil Puronr R---410A Refrigerant

Voltage

E = 460/3/60

P = 208/230/3/60

T = 575/3/60

Nominal Tonnage

25 = 20 Tons

28 = 25 Tons

30 = 30 Tons

Type of Coil

A = Standard DX Coil

B = High Capacity DX Coil

H = DX Coil for Heat Pump Duty

Not Used

0 = Not Used

Not Used

0 = Not Used

Packaging

A = Standard

Not Used

A = Not Used

Service Options

A = None

B = Painted Cabinet

Not Used

0 = Not Used

Indoor Fan Options

1 = Fan Drive and Motor - Low / Motor Efficency - Standard 2 = Fan Drive and Motor - Med / Motor Efficency - Standard 3 = Fan Drive and Motor - High / Motor Efficency - Standard

Coil Options

A = Al/Cu

Not Used

0 = Not Used

524J

 

 

 

Fig. 3 - Model Number Nomenclature

 

 

 

 

C10837

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION NUMBER

 

1

 

2

3

4

 

5

 

6

 

7

 

8

9

10

TYPICAL

 

2

 

6

1

0

 

G

 

1

 

2

 

3

4

5

 

POSITION

 

 

 

 

DESIGNATES

 

 

 

 

 

 

 

1−2

 

 

 

 

Week of manufacture (fiscal calendar)

 

 

 

 

 

3−4

 

 

 

 

Year of manufacture (“10” = 2010)

 

 

 

 

5

 

 

 

Manufacturing location (G = ETP, Texas, USA)

 

 

 

 

6−10

 

 

 

 

 

Sequential number

 

 

 

 

 

Fig. 4 - Serial Number Nomenclature

C!0725

TXV

COIL

horizontally and the supply air discharging horizontally. When applying the unit in a horizontal arrangement, ensure the condensate drain pan is located at the bottom center of the unit for adequate condensate disposal. See Fig. 6 for condensate connections for each unit position.

REMOVE FOAM BLOCK

PLUG

Fig. 4 - Serial Number NomenclatureFig. 5 - Foam Block Location PLUG

CONDENSATE

DRAIN

LEGEND

TXV — Thermostatic Expansion Valve

C10683

Fig. 5 - Foam Block Location

Unit Positioning - The unit can be mounted on the floor for vertical application with return air entering the face of the unit and supply air discharging vertically through the top of the unit. The unit can also be applied in a horizontal arrangement with return air entering

LEGEND

Accessory Line

Alternate Air Intake and Discharge

Air Intake and Discharge

Note: Maintain recommended clearances per Fig. 1 and Fig. 2

C10684

Fig. 6 - Typical Unit Positioning

9

Page 9