PERFORMANCE DATA (cont)

COMBINATION RATINGS

UNIT 566D150

 

 

 

566D150/524A-C150 WITH HIGH CAPACITY 4-ROW COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

Evaporator Air — Cfm

 

 

 

 

 

 

 

 

 

Air Entering

 

 

 

3750

 

 

 

 

5000

 

 

 

 

6250

 

 

 

 

Condenser

 

 

 

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

62

 

67

72

57

 

62

 

67

 

72

57

62

 

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

133.0

 

139.0

 

151.0

165.0

146.0

 

147.0

 

158.0

 

172.0

154.0

154.0

 

163.0

177.0

 

 

 

80

 

SHC

133.0

 

123.0

 

103.0

83.1

146.0

 

142.0

 

119.0

 

92.7

154.0

154.0

 

133.0

101.0

 

 

 

 

 

kW

9.00

 

9.07

 

9.27

9.48

9.18

 

9.20

 

9.38

 

9.59

9.32

9.32

 

9.45

9.66

 

 

 

 

 

TC

131.0

 

136.0

 

148.0

161.0

143.0

 

144.0

 

155.0

 

169.0

152.0

151.0

 

160.0

173.0

 

 

 

85

 

SHC

131.0

 

122.0

 

102.0

81.9

143.0

 

140.0

 

117.0

 

91.3

152.0

151.0

 

131.0

100.0

 

 

 

 

 

kW

9.44

 

9.54

 

9.75

9.99

9.66

 

9.69

 

9.88

 

10.10

9.82

9.81

 

9.96

10.20

 

 

 

 

 

TC

126.0

 

130.0

 

142.0

155.0

138.0

 

138.0

 

148.0

 

161.0

146.0

146.0

 

153.0

165.0

 

 

 

95

 

SHC

126.0

 

119.0

 

99.5

79.3

138.0

 

137.0

 

115.0

 

88.8

146.0

146.0

 

128.0

97.5

 

 

 

 

 

kW

10.40

 

10.50

 

10.70

11.00

10.60

 

10.60

 

10.90

 

11.20

10.80

10.80

 

11.00

11.30

 

 

 

 

 

TC

123.0

 

127.0

 

138.0

151.0

135.0

 

135.0

 

145.0

 

157.0

143.0

143.0

 

149.0

161.0

 

 

 

100

 

SHC

123.0

 

117.0

 

98.2

78.0

135.0

 

134.0

 

113.0

 

87.5

143.0

143.0

 

127.0

96.2

 

 

 

 

 

kW

10.80

 

10.90

 

11.20

11.50

11.10

 

11.10

 

11.30

 

11.70

11.30

11.30

 

11.50

11.80

 

 

 

 

 

TC

121.0

 

124.0

 

135.0

148.0

132.0

 

132.0

 

141.0

 

154.0

140.0

140.0

 

145.0

157.0

 

 

 

105

 

SHC

121.0

 

116.0

 

96.8

76.8

132.0

 

132.0

 

112.0

 

86.1

140.0

140.0

 

125.0

94.8

 

 

 

 

 

kW

11.30

 

11.40

 

11.70

12.00

11.60

 

11.60

 

11.80

 

12.20

11.80

11.80

 

12.00

12.30

 

 

 

 

 

TC

116.0

 

118.0

 

129.0

141.0

127.0

 

127.0

 

134.0

 

146.0

134.0

134.0

 

138.0

149.0

 

 

 

115

 

SHC

116.0

 

113.0

 

94.1

74.2

127.0

 

127.0

 

109.0

 

83.5

134.0

134.0

 

122.0

92.2

 

 

 

 

 

kW

12.20

 

12.30

 

12.60

13.00

12.50

 

12.50

 

12.80

 

13.20

12.80

12.80

 

12.90

13.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

566D150/524A-B150 WITH STANDARD 3-ROW COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp (F)

 

 

 

 

 

 

 

Evaporator Air — Cfm

 

 

 

 

 

 

 

 

 

Air Entering

 

 

 

3750

 

 

 

 

5000

 

 

 

 

6250

 

 

 

 

Condenser

 

 

 

 

 

 

Evaporator Air — Ewb (F)

 

 

 

 

 

 

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

 

62

 

67

72

57

 

62

 

67

 

72

57

62

 

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

127.0

 

134.0

 

146.0

160.0

140.0

 

142.0

 

153.0

 

167.0

148.0

148.0

 

158.0

172.0

 

240-

 

80

 

SHC

127.0

 

118.0

 

99.4

80.2

140.0

 

136.0

 

114.0

 

89.0

148.0

148.0

 

126.0

96.9

 

 

 

 

 

kW

8.93

 

9.01

 

9.19

9.40

9.09

 

9.12

 

9.31

 

9.51

9.22

9.22

 

9.37

9.58

 

566D/E150

 

85

 

TC

125.0

 

131.0

 

143.0

156.0

137.0

 

139.0

 

150.0

 

163.0

145.0

145.0

 

154.0

168.0

 

 

 

TC

118.0

 

122.0

 

134.0

146.0

129.0

 

130.0

 

140.0

 

152.0

137.0

137.0

 

144.0

156.0

 

 

 

 

SHC

125.0

 

117.0

 

98.2

78.9

137.0

 

134.0

 

112.0

 

87.6

145.0

145.0

 

125.0

95.6

 

 

 

 

 

kW

9.37

 

9.45

 

9.67

9.90

9.55

 

9.58

 

9.79

 

10.00

9.70

9.71

 

9.87

10.10

 

 

 

 

 

TC

121.0

 

125.0

 

137.0

150.0

132.0

 

133.0

 

143.0

 

156.0

140.0

140.0

 

147.0

160.0

 

 

 

95

 

SHC

121.0

 

114.0

 

95.6

76.4

132.0

 

130.0

 

110.0

 

85.1

140.0

140.0

 

122.0

93.0

 

 

 

 

 

kW

10.30

 

10.30

 

10.60

10.90

10.50

 

10.50

 

10.70

 

11.00

10.70

10.70

 

10.80

11.10

 

 

 

100

 

SHC

118.0

 

112.0

 

94.3

75.2

129.0

 

128.0

 

108.0

 

83.8

137.0

137.0

 

121.0

91.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

10.70

 

10.80

 

11.10

11.40

11.00

 

11.00

 

11.20

 

11.60

11.20

11.20

 

11.30

11.70

 

 

 

 

 

TC

116.0

 

119.0

 

131.0

143.0

127.0

 

127.0

 

136.0

 

149.0

134.0

134.0

 

140.0

153.0

 

 

 

105

 

SHC

116.0

 

111.0

 

92.9

73.9

127.0

 

126.0

 

107.0

 

82.5

134.0

134.0

 

119.0

90.4

 

 

 

 

 

kW

11.20

 

11.20

 

11.50

11.90

11.40

 

11.40

 

11.70

 

12.10

11.60

11.60

 

11.80

12.20

 

 

 

 

 

TC

111.0

 

113.0

 

124.0

136.0

121.0

 

121.0

 

129.0

 

141.0

128.0

128.0

 

133.0

145.0

 

 

 

115

 

SHC

111.0

 

108.0

 

90.3

71.4

121.0

 

121.0

 

104.0

 

79.9

128.0

128.0

 

116.0

87.8

 

 

 

 

 

kW

12.00

 

12.10

 

12.50

12.90

12.40

 

12.40

 

12.60

 

13.10

12.60

12.60

 

12.80

13.20

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edb —

Entering Dry Bulb

Ewb —

Entering Wet Bulb

kW —

Compressor Motor Power Input

SHC —

Sensible Heat Capacity (1000 Btuh) Gross

TC —

Total Capacity (1000 Btuh) Gross

40

Page 40
Image 40
Bryant 576C Unit 566D150, 566D150/524A-C150 with High Capacity 4-ROW Coil, Edb, 566D150/524A-B150 with Standard 3-ROW Coil

569F, 566E, 566D, 569D, 576C specifications

Bryant has long been recognized for its innovative heating and cooling solutions, and the Bryant 576C, 569D, 566D, 566E, and 569F models exemplify the brand's commitment to energy efficiency, comfort, and advanced technology. Each model is designed to cater to various residential and commercial heating and cooling needs, ensuring optimal performance and reliability.

The Bryant 576C is a highly efficient air conditioning unit that offers remarkable SEER ratings, making it an eco-friendly choice for homeowners. Its advanced technology includes a variable-speed compressor, which adjusts the cooling output based on the home’s requirements, ensuring maximum comfort while minimizing energy consumption. Additionally, its Quiet operation allows for a peaceful indoor environment, as the system operates at low sound levels even during peak performance.

The Bryant 569D heating system stands out for its durability and energy efficiency. Designed with a two-stage gas valve, it provides flexible heating output, allowing for improved temperature control. This model is equipped with an ECM blower motor, ensuring quiet operation and consistent airflow. Its efficiency ratings are impressive, providing significant savings on energy bills while maintaining an ideal indoor climate.

Similarly, the Bryant 566D model emphasizes performance and reliability. Its variable-speed blower motor enhances comfort levels by providing better humidity control and even heating throughout the living space. With an emphasis on high-quality construction materials, this model ensures a long lifespan, making it a wise investment for homeowners looking for effective heating solutions.

The Bryant 566E model incorporates state-of-the-art technology, including smart thermostat compatibility, which allows users to control their heating and cooling systems remotely. This feature enhances convenience and helps to optimize energy usage based on the occupants' schedules. With its excellent design and efficiency, the 566E is perfect for those seeking a modern heating solution without compromising on comfort.

Lastly, the Bryant 569F is ideal for homeowners wanting a balance between efficiency and performance. With an ENERGY STAR certification, this model provides reliable heating while keeping energy costs low. Its compact design makes it suitable for various spaces, and the integrated safety features ensure peace of mind for users.

In summary, whether you choose the Bryant 576C, 569D, 566D, 566E, or 569F, each model reflects a commitment to quality, efficiency, and innovation, ensuring that homeowners can achieve the perfect climate in their living spaces. These heating and cooling systems leverage advanced technologies that not only provide comfort but also promote energy savings and environmental responsibility.