Bryant 566D, 576C, 566E, 569F Typical Wiring Schematics, 569D090, 208/230-3-360 and 460-3-60 Units

Models: 569F 566E 566D 569D 576C

1 84
Download 84 pages 60.46 Kb
Page 9
Image 9

TYPICAL WIRING SCHEMATICS

NOTES:

1. If any of the original wire furnished must be replaced, it must be replaced with type 90° C wire or its equivalent.

2.Thermostat: HH07AT170, 172, 174 & P272-

2783

Subbase: HH93AZ176, 178 & P272-1882, 1883 or HH93AZ177 & 179.

3. Sealed VA for IFC and LLSV is not to exceed 22.

4.Use copper conductors only.

5.TRAN is wired for 230 v unit. If unit is to be run with 200 v power supply, disconnect BLK wire from 230 v tap and connect to 200 v tap.

6.If TRAN is wired for 460-3-60 v and unit is to be run with 400-3-50 v power supply, disconnect BLK wire from 460 v tap and connect to 400 v tap.

7.Three-phase motors are protected under pri- mary single phasing conditions.

VOLTAGE

CB

 

MUST

RATING

Mfg. Part No.

 

TRIP

 

AMPS

24 V

Potter & Brumfield

 

3.2

 

W28X-1024-3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

AHA

Adjustable Heat Anticipator

LLSV

Liquid Line Solenoid Valve

 

 

 

 

Terminal (Marked)

 

 

 

 

C

Contactor, Compressor

LPS

Low-Pressure Switch

 

 

 

 

 

 

 

 

Terminal (Unmarked)

CAP

Capacitor

NEC

National Electrical Code

 

 

 

 

 

 

 

CB

Circuit Breaker

OFM

Outdoor-Fan Motor

 

 

 

 

 

Terminal Block

CC

Cooling Compensator

QT

Quadruple Terminal

 

 

 

 

 

 

 

 

 

 

Splice

 

 

 

 

 

CH

Crankcase Heater

TB

Terminal Block

 

 

 

 

 

 

 

 

CLO

Compressor Lockout

TC

Thermostat-Cooling

 

 

 

 

Factory Wiring

COMP

Compressor Motor

TH

Thermostat-Heating

— —

 

Field Control Wiring

DGT

Discharge Gas Thermostat

TRAN

Transformer

 

 

 

 

 

Field Power Wiring

EQUIP

Equipment

 

 

 

 

 

Field Splice

 

 

 

 

 

 

 

 

 

 

 

 

GND

Ground

 

 

 

 

 

 

 

 

 

Accessory or Optional Wiring

 

 

 

 

 

 

 

 

 

 

 

HPS

High-Pressure Switch

 

 

 

 

 

Marked Wire

 

 

 

 

To Indicate Common Potential

 

 

 

 

 

 

 

 

 

IFC

Indoor-Fan Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only, Not Represent Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

569D090, 208/230-3-360 and 460-3-60 Units

9

Page 9
Image 9
Bryant 566D, 576C, 566E, 569F manual Typical Wiring Schematics, 569D090, 208/230-3-360 and 460-3-60 Units

569F, 566E, 566D, 569D, 576C specifications

Bryant has long been recognized for its innovative heating and cooling solutions, and the Bryant 576C, 569D, 566D, 566E, and 569F models exemplify the brand's commitment to energy efficiency, comfort, and advanced technology. Each model is designed to cater to various residential and commercial heating and cooling needs, ensuring optimal performance and reliability.

The Bryant 576C is a highly efficient air conditioning unit that offers remarkable SEER ratings, making it an eco-friendly choice for homeowners. Its advanced technology includes a variable-speed compressor, which adjusts the cooling output based on the home’s requirements, ensuring maximum comfort while minimizing energy consumption. Additionally, its Quiet operation allows for a peaceful indoor environment, as the system operates at low sound levels even during peak performance.

The Bryant 569D heating system stands out for its durability and energy efficiency. Designed with a two-stage gas valve, it provides flexible heating output, allowing for improved temperature control. This model is equipped with an ECM blower motor, ensuring quiet operation and consistent airflow. Its efficiency ratings are impressive, providing significant savings on energy bills while maintaining an ideal indoor climate.

Similarly, the Bryant 566D model emphasizes performance and reliability. Its variable-speed blower motor enhances comfort levels by providing better humidity control and even heating throughout the living space. With an emphasis on high-quality construction materials, this model ensures a long lifespan, making it a wise investment for homeowners looking for effective heating solutions.

The Bryant 566E model incorporates state-of-the-art technology, including smart thermostat compatibility, which allows users to control their heating and cooling systems remotely. This feature enhances convenience and helps to optimize energy usage based on the occupants' schedules. With its excellent design and efficiency, the 566E is perfect for those seeking a modern heating solution without compromising on comfort.

Lastly, the Bryant 569F is ideal for homeowners wanting a balance between efficiency and performance. With an ENERGY STAR certification, this model provides reliable heating while keeping energy costs low. Its compact design makes it suitable for various spaces, and the integrated safety features ensure peace of mind for users.

In summary, whether you choose the Bryant 576C, 569D, 566D, 566E, or 569F, each model reflects a commitment to quality, efficiency, and innovation, ensuring that homeowners can achieve the perfect climate in their living spaces. These heating and cooling systems leverage advanced technologies that not only provide comfort but also promote energy savings and environmental responsibility.