Bryant A07049, A07048 Configuration Options -Selection, Option 01 Equipment Type

Models: A07048 A07049

1 84
Download 84 pages 61.06 Kb
Page 27
Image 27

saved at the time of selection and will be saved in the event of the 3 minute time-out or when installer exits from configuration menu.

Configuration Options —Selection

Option 01 — Equipment Type

Range: H2, A2, HP, AC, hh, h2, H, C

H2 — operates a two-speed heat pump with a fan coil

HP — operates a single-speed heat pump with a fan coil

A2 — operates a two-speed AC

AC — operates a single-speed AC

hh— operates a single-speed heat pump with a furnace

h2 — operates a two-speed heat pump with a furnace

H— operates a heat-only system. Furnace or fan coil only; no outdoor unit.

C— operates a cool only-system. Outdoor AC unit with an indoor fan coil with no strip heaters.

Default is H2.

Option 02 — Clean Filter Timer

Select hours of blower operation (heating, cooling, or fan) before CHECK FILTER icon is displayed. With OF selected, icon will never come on, disabling this feature. Time selection can range from 800 to 7200 hr by selecting numbers 1 through 9. (Time is 800 X number selected.) Default is 4 (3200 hr).

Recommended selections are disposable filter-800 to 2400 hr, media filter-2400 to 3200 hr, or electronic air cleaner-1600 to 2400 hr of blower operation. For higher efficiency filter, please consult filter’s Installation Instruction for details.

27

Page 27
Image 27
Bryant A07049, A07048 Configuration Options -Selection, Option 01 Equipment Type, Option 02 Clean Filter Timer