saved at the time of selection and will be saved in the event of the 3 minute
Configuration Options —Selection
Option 01 — Equipment Type
Range: H2, A2, HP, AC, hh, h2, H, C
H2 — operates a
HP — operates a
A2 — operates a
AC — operates a
hh— operates a
h2 — operates a
H— operates a
C— operates a cool
Default is H2.
Option 02 — Clean Filter Timer
Select hours of blower operation (heating, cooling, or fan) before CHECK FILTER icon is displayed. With OF selected, icon will never come on, disabling this feature. Time selection can range from 800 to 7200 hr by selecting numbers 1 through 9. (Time is 800 X number selected.) Default is 4 (3200 hr).
Recommended selections are disposable
27