pressed for fan to turn On and off. On some fan coils, fan continues to operate for 90 sec after G signal is removed.

Final Settings

Be sure to press DONE to exit installer setup mode. If the system is to be left in operation after installation is complete, use MODE button to select between HEAT, COOL, or AUTO to provide desired operation of heating, cooling, or auto.

On the programmable models, the default setpoints and programmed schedule conform to the Energy Starr requirements of the U.S. Department of Energy for both heating and cooling. These provide energy saving temperature settings. Refer to Table 1.

Table 1 – Energy Star Default Schedule

SCHEDULE

HEAT

COOL

Wake 6:00 AM

68_F/20_C

78_F/26_C

Day 8:00 AM

60_F/16_C

85_F/29_C

Evening 5:00 PM

68_F/20_C

78_F/26_C

Sleep 10:00 PM

60_F/16_C

82_F/28_C

If the programmed schedule is to be used, make sure the triangle icon next to the FOLLOW SCHEDULE icon is turned on. Pressing the Schedule button will cycle the triangle icon through the FOLLOW SCHEDULE, HOLD and VACATION selections.

If fixed temperatures are desired, use SCHEDULE button to turn on arrow icon next to HOLD. This will maintain setpoints, not allowing them to change with programmed schedule.

45

Page 45
Image 45
Bryant A07049, A07048 installation instructions Final Settings, Energy Star Default Schedule

A07048, A07049 specifications

The Bryant A07049 and A07048 are notable entries in the line of ductless mini-split systems designed for efficient heating and cooling. These models are well-regarded for their robust performance and innovative features that cater to both residential and light commercial applications.

One of the main features of the Bryant A07049 and A07048 is their advanced inverter technology. This technology allows the units to modulate their compressor speed, resulting in a more consistent indoor temperature. By adjusting cooling or heating output based on real-time demand, the units enhance energy efficiency while providing quiet operation and improved comfort.

The cooling capacity of the Bryant A07049 is rated at 7,000 BTUs, making it suitable for medium-sized rooms, whereas the A07048 has a slightly lower capacity, ideal for smaller spaces. Both models excel in providing rapid temperature control, allowing users to enjoy their desired environment swiftly. The quiet operation is a significant advantage, with sound levels as low as 24 decibels, making them perfect for bedrooms, offices, or other noise-sensitive environments.

Installation flexibility is another remarkable characteristic of the Bryant A07049 and A07048. Their ductless design eliminates the need for extensive ductwork, simplifying installation processes. Both models come with easy-mount wall brackets, and the refrigerant lines can be run through a small, discreet opening in the wall, maintaining the aesthetic appeal of the living space.

Energy efficiency is a standout feature of these models, boasting high Seasonal Energy Efficiency Ratio (SEER) ratings. This high-efficiency operation not only reduces energy bills but also minimizes environmental impact. Additionally, both models include a built-in programmable thermostat that allows users to schedule their heating and cooling preferences, enhancing convenience and further optimizing energy use.

The Bryant A07049 and A07048 also feature a multi-stage filtration system. This advanced filtration captures dust, allergens, and other particulate matter, promoting cleaner air circulation which is particularly beneficial for those with allergies or respiratory conditions.

In summary, the Bryant A07049 and A07048 mini-split systems deliver versatility, energy efficiency, and user-friendly operation. Their modern design, quiet performance, and advanced technologies make them excellent choices for individuals or businesses looking to enhance comfort while being mindful of energy consumption. Whether used for supplementary heating or cooling, these units are engineered to meet a variety of climate control needs effectively.