Auto-fill Cleaning Instructions

(With Brixing Pump Installed)

Materials required

1.Non-sudsing liquid detergent (such as common household automatic dishwasher liquid detergent).

2.Household bleach (Sodium chloride solution: 5.25%) or equivalent.

3.Clean five (5) gallon bucket.

4.Measuring Cup

5.An adaptor is needed to hold the Q.C.D. fitting on the concentrate suction line open. A connector from an empty bag will work.

Sanitizing Procedure

1.Fill bucket with 4 gallons of warm water (120-180 deg. F).

2.Measure 4 ounces (1/2 cup) of the liquid detergent and add to the water.

3.Measure 2 ounces (1/4 cup) of bleach and add to the water, then stir, mixing evenly.

4.Ensure that the refill for the Ultra hopper is turned off.

5.Empty all product from the Ultra hopper

6.Disconnect the concentrate line from the B-I-B and install adaptor on the quick disconnect so the line is open to the sanitizing solution. Place concentrate inlet line into the bucket to that the Q.C.D. will stay at the bottom.

7.Press the auger button to turn on the “Auger Refill On” feature.

8.Allow system to run until the hopper is about 1/4 full then turn off refill.

9.Switch three way sanitize valve to the Sanitize postion.

10.Turn refill system back on and let run until the hopper is almost full then turn off refill.

11.Allow sanitizer to sit in system for 10 minutes.

12.Drain sanitizer from hopper and remove the Q.C.D. from the sanitizer bucket.

13.Empty remaining sanitizer and refill bucket with about 2 gallons of warm (120-180 deg. F) rinse water.

14.Turn sanitize valve back to dispense position.

15.Place Q.C.D. into rinse water and turn on refill system.

16.Run until hopper is about 1/4 full.

17.Turn off refill system and drain hoppers.

18.Refer to the recommended daily cleaning instructions on page 26 and follow these steps to clean the hopper, lid and other dispense parts.