PROGRAMMING THE DISPENSER

PROGRAMMING THE DISPENSER

Open the dispenser door to access the digital programming module with LED display. Two basic modes are available to the operator: Display Mode and Program Mode.

To enter the Display Mode, Set the RUN/NIGHT/PROGRAM Switch to the RUN position.

To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position.

Display Mode: Used to view the current set-up values. Use the MENU switch to scroll to the next display.

NOTE: The display blanks out after two minutes of inactivity. Press any button to activate the display.

LCD DISPLAY

LCD DISPLAYDISPLAY MODEDESCRIPTIONHome View1050.08Manual background0

MENU

(-)

(+)

 

 

 

 

 

 

0

1

1

8

0

MENU

(-)

(+)

 

 

 

 

0

2

 

 

3

0

MENU

(-)

(+)

 

 

 

 

0

3

 

 

3

0

MENU

(-)

(+)

 

 

 

 

0

4

 

 

0.

0

DISPLAY MODE

DESCRIPTION

Home View

DisplaysTank Temperature.

Tank Temperature

Displays target Tank Temperature (F°)

Regular Dispense Ratio

Displays Left Dispense Ratio (XXX:1)

Decaf Dispense Ratio

Displays Right Dispense Ratio (XXX:1)

Cup Dispense Volume

Displays Cup Dispense Volume (XX.X

 

Oz.). Set to 0.0 for “Push and Hold”

 

Dispense Mode.

MENU (-) (+)

0Manual background5Manual backgroundManual backgroundManual background0.Manual background0

Carafe Dispense Volume

Displays Carafe Dispense Volume

 

(XX.X Oz.)

MENU (-) (+)