CALIBRATING THE DISPENSER (Cont.)
LCD DISPLAY
C4 r un
MENU
C41. 0 8
MENU
C6 20 0
MENU
C7Eng
MENU
C8 - - -
MENU
C9 - - -
MENU
LC xx
CALIBRATION MODE | DESCRIPTION |
Right (Decaf) Water Rate | Set |
| RINSE position. Press and hold Decaf |
| Dispense Switch until flow stops (20 |
| sec.) Refer to Field Calibration of the |
| Concentrate Pumps. |
Right (Decaf) Water Rate | Enter Liters collected from the 20 sec. |
| test above. |
| Default = 1.08 |
| Range = 0.95 - 1.12 Liters |
Pump “OFF” Delay | Delays the Pump turn off after a |
| dispense. |
| Default = 200 |
| Range = 1 - 999 mSec. |
English or Metric Mode | Eng for English |
| S.I. for Metric |
Error Code History | Displays last known Error Code |
| Depress the Decrease |
| last 3 Errors. |
| Hold the Decrease |
| switches for 10 sec. to Erase. |
Reset Factory Defaults | Resets all set up values to the Factory |
| Default setting. |
| Hold both Increase (+) and Decrease |
| |
| Displays Software Version # - |
| Exits To Home View After 3 Seconds. |
MENU
21 | 38791 072307 |
|