Program Mode (Continued)

PROGRAMMING THE DISPENSER (Cont.)

Program Mode (Continued)

LCD DISPLAY

P 7Right (Decaf) Dispense TotalP 860 0P 9OFF0.LC0xx0

PROGRAM MODE

DESCRIPTION

Right (Decaf) Dispense Total

Reset Total to Zero (00.0 Gal)

MENU (-) (+)

PPPLOC 8PROGRAM FUNCTIONManual background6Manual background0Manual background 0

MENU (-) (+)

PManual background 9Manual backgroundManual backgroundOFManual backgroundF

MENU (-) (+)

LCManual backgroundManual background0Manual backgroundxManual backgroundx

Empty Product Threshold

Set Conductance Threshold

 

Default = 600

 

Range = 100 Min / 900 Max

 

To check Conductance of Hot Water,

 

view the display while rinsing. Set value

 

to 100 above reading.

Rinse Alarm Timer

Default = OFF > Rinse Alarm Disabled

 

Range = 1 - 24 hrs

 

Reminder Only. No Lock Out.

 

To clear alarm, set to RINSE Mode.

 

Press Left switch, then Right switch

 

for 15 seconds each.

 

Displays Software Version # -

 

Exits To Home View After 3 Seconds.

MENU (-) (+)

Program Lockout Function: The operator must hold down the stop and portion control button for 10 sec- onds while machine is in program mode. At 10 seconds, the machine's display changes from "PPP" to "PP LOC" indicating the locked position. At this point, the operator may view the setup functions, but not alter any of the parameters. In order to unlock the machine, repeat the aforementioned process. A MemoryLocked flag is set in eeprom so that the machine will retain this setting if power is lost.

LCD DISPLAY

PPManual backgroundManual backgroundLOC

PROGRAM FUNCTION

 DESCRIPTION

Function Lockout Feature

Prevents the user from changing set-up

 

functions