Bunn 38791.0000K EC007, EC010, EC011, TROUBLESHOOTING GUIDE Cont Error Codes Continued

Models: 38791.0000K

1 26
Download 26 pages 36.94 Kb
Page 23
Image 23
TROUBLESHOOTING GUIDE (Cont.)

TROUBLESHOOTING GUIDE (Cont.)

Error Codes (Continued)

LED DISPLAY

ECEC0 0 7EC0 1 00EC011 0Manual background 7

ERROR

DESCRIPTION/TROUBLESHOOTING

Tank Temp Sensor Failed

Sensor Reading Out Of Range (High

 

or Low). Faulty Sensor wiring.

MENU (-) (+)

EManual backgroundCManual backgroundManual background0Manual background 1Manual background 0

MENU (-) (+)

EManual backgroundCManual backgroundManual background0Manual background1Manual background1

MENU (-) (+)

Switch Board Failure

Unable To Communicate With The

 

Switch Board In The Door. Faulty

 

wiring between the Door and the Main

 

Control Board.

Power Supply Voltage Out of

Too High (>26 Vdc) or Too Low (<23

Range

Vdc) Display alternates between

 

EC-011 and the actual power supply

 

voltage, (XX Vdc). Check line voltage.

 

Check 115/230 Vac switch on the

 

power supply.

23

38791 040306

 

Page 23
Image 23