| Model | |
|
|
| |||
| SECTION 4. TROUBLESHOOTING |
| |||
|
|
|
| ||
PROBLEM |
|
| CAUSE | CORRECTION |
|
Product not |
| • | Doors are not kept closed | • Keep doors closed when | |
holding |
|
|
| possible | |
temperature |
|
| Product held too long | • Only hold product for | |
|
| • | |||
|
|
|
| recommended times | |
|
| • | Water temperature too low | • Turn to higher setting | |
|
| • | Radiant heat too low | • Turn to higher setting | |
|
| • | Light bulbs out | • Replace as required, per | |
|
|
|
| Light Bulbs and Glass Panels | |
|
|
|
| Section | |
|
|
|
|
|
|
Doors are |
| • | Doors left open too much | • Keep doors closed when | |
fogging |
|
| allowing doors to cool and | possible | |
|
|
| cause condensation |
|
|
|
| • | Radiant heat not high enough | • Turn to higher setting | |
|
| • | Water temperature too high | • See recommended settings | |
|
|
|
| and temperatures | |
|
|
|
|
|
|
Water will |
| • | Water supply has been shut- | • Check the water supply | |
notfill |
|
| off or disconnected |
|
|
|
|
|
|
|
|
Lightswill |
| • | Defective fuse | • Replace 15 amp fuse | |
not turn on |
|
|
|
|
|
|
|
|
|
|
|
Not all lights |
| • | Faulty light bulbs | • Replace with recommended | |
on |
|
|
| bulb, per Light Bulbs and Glass | |
|
|
|
| Panels Section | |
|
|
|
|
|
|
Water will not |
| • | Bun pans are not over water | • Place perforated bun pans | |
reach desired |
|
|
| over water | |
temperature |
|
|
|
|
|
|
|
|
|
|
|
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,
or
203 |