Model
| The drain can be connected to a 1 inch N.P.T. directly below |
| the water well or to a 3/4 inch N.P.T. from the operator’s side. |
| We recommend the 1 inch N.P.T. connection as this allows |
| straight down draining of the water. |
This unit must be adequately and safely grounded. Refer to local electrical codes for correct grounding procedures. If unit is not adequately grounded, electrical shock could result.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be bonded to other appliances or touchable metal surfaces in close proximity to this appliance with an equipotential bonding conductor. This appliance is equipped with an equipotential lug for this purpose. The equipotential lug is marked with the following symbol
A separate disconnect switch with proper capacity fuses or breakers must be installed at a convenient location between the cabinet and the power source. The field supply wiring to the cabinet should be an insulated copper conductor rated for 600 volts and 90ºC.
1004 |