2-5. DRAIN CONNECTION

Model CW-216/CW-114

2-5. DRAIN CONNECTION

The drain can be connected to a 1 inch N.P.T. directly below

 

the water well or to a 3/4 inch N.P.T. from the operator’s side.

 

We recommend the 1 inch N.P.T. connection as this allows

 

straight down draining of the water.

2-6. ELECTRIC CONNECTION The display counter warmer is available from the factory wired for 208 or 230 volts, single phase 3-wire (includes neutral) or three phase 4-wire (includes neutral) 60 Hertz service. The proper power service cable must be provided at installation. Check the data plate on the side panel of the control end to determine the correct power supply.

This unit must be adequately and safely grounded. Refer to local electrical codes for correct grounding procedures. If unit is not adequately grounded, electrical shock could result.

(FOR EQUIPMENT WITH CE MARK ONLY!)

To prevent electric shock hazard this appliance must be bonded to other appliances or touchable metal surfaces in close proximity to this appliance with an equipotential bonding conductor. This appliance is equipped with an equipotential lug for this purpose. The equipotential lug is marked with the following symbol (FOR EQUIPMENT WITH CE MARK ONLY!)

A separate disconnect switch with proper capacity fuses or breakers must be installed at a convenient location between the cabinet and the power source. The field supply wiring to the cabinet should be an insulated copper conductor rated for 600 volts and 90ºC.

2-4