2-3. LOCATION

Model CW-216/CW-114

2-3. LOCATION

Place the unit on a table, preferably with a cut-out opening below

 

the cabinet to allow easy service connections and serviceability.

 

When setting up the Henny Penny Display Counter Warmer,

 

be sure to level the table.

The unit has built-in draining capabilities, but this becomes ineffective when set on an unlevel table.

After the Henny Penny Display Counter Warmer has been leveled on the table, run a bead of silicone rubber (or equivalent sealant) around the perimeter of the unit, sealing it to the table top. You are now ready to make the electrical and drain connections to the unit.

2-4. REMOVE CONTROL END

1.

Remove the seven screws fastening the end panel to the

PANEL

 

cabinet.

 

2.

Slide bottom of end panel out first allowing top to drop

 

 

below shelf edge.

Step 2