PROGRAMMING THE DISPENSER (Cont.)
Program Mode: Used to change or enter new
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will display “__PPP” to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use the Increase (+) and Decrease
LCD DISPLAY
P 1180
MENU
P230
MENU
P3 3 0
MENU
P40. 0
MENU
P50. 0
MENU
P60. 0
PROGRAM MODE | DESCRIPTION |
Tank Temperature | Default = 180°F |
| Range = 120° - 200°F |
| Ready Temp = Tank Temp minus 10°F |
Left (Regular) Dispense Ratio | Set Regular Coffee Ratio |
| Default = 30:1 |
| Range = 25 Max / 100 Min |
Right (Decaf) Dispense Ratio | Set Decaf Coffee Ratio |
| Default = 30:1 |
| Range = 25 Max / 100 Min |
Cup Dispense Volume | Set Cup Dispense Volume |
| Default = 0.0, Push & Hold |
| Range = 0.0 / 16.0 Oz. |
Carafe Dispense Volume | Set Carafe Dispense Volume |
| Default = 0.0, Disabled |
| Range = 0.0 / 64.0 Oz. |
Left (Regular) Dispense Total | Reset Total to Zero (00.0 Gal) |
MENU
14 | 38791 072307 |
|