Bunn AFPO-3 SL Pump Flavor On/Off Switches, #1 AFPO-2, #2 AFPO-2, #3 AFPO-3 ONLY, SERVICE cont

Models: AFPO-3 SL

1 25
Download 25 pages 51.21 Kb
Page 14
Image 14
PUMP (FLAVOR) ON/OFF SWITCHES

SERVICE (cont.)

PUMP (FLAVOR) ON/OFF SWITCHES

 

1

 

2

 

3

 

1

 

1

 

2

2

3

3

 

 

P1521

FIG.12 PUMP (FLAVOR) START SWITCHES

Location:

The pump (flavor) START switches are located on the switch mounting plate inside the autofill box on the right side.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Disconnect the wires from the switch to be tested.

3.Check for continuity across the terminals on the switch when it is held in the on position. Continuity must not be present across these terminals in the released position.

If continuity is present as described, reconnect the wires to the switch.

If continuity is not present as described, replace the switch.

Removal and Replacement:

1.Disconnect the dispenser from the power source.

2.Remove the wires from the switch terminals.

3.Compress the clips inside the autofill box and gently push the switch through the opening.

4.Push the new switch into the opening and spread the clips to hold switch in the autofill box.

5.Refer to Fig. 13 when reconnecting the wires.

#1 AFPO-2 & 3

#1 AFPO-2 & 3 BLK from Solenoid Switch #1

BLK to Test/Operate Switch

RED/BLK to Test/Operate Switch

YEL to Pump #1

#2 AFPO-2 & 3

#2 AFPO-2 & 3 BLK from Solenoid Switch #1

BLK to Solenoid Switch #2

BRN/BLK to Test/Operate Switch

ORN to Pump #2

#3 AFPO-3 ONLY

#3 AFPO-3 ONLY BLK from Solenoid Switch #2

BLK to Solenoid Switch #3

WHI/RED to Test/Operate Switch

RED to Pump #3

P1524

FIG. 13 PUMP (FLAVOR) SWITCH TERMINALS

14

41093 040408

 

Page 14
Image 14