TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Product will not dispense (cont.) | 6. Main ON/OFF switch | Refer to Service - Main ON/OFF |
|
| Switch for testing procedure. See |
|
| page 13 |
| 7. Probe box LOW/OFF/HIGH switch- | Refer to Service - Probe system. |
| es | See page 14 |
| 8. Circuit board | Refer to Service - Circuit Board for |
|
| testing procedures. See page 11 |
| 9. Vacuum switch | Refer to Service - Vacuum switch for |
|
| testing procedures. See page 22 |
| 10. Vacuum/Supply pump | Refer to Service - Vacuum/Supply |
|
| pump for testing procedures. See |
|
| page 20 |
| 11. Pump (flavor) start switches | Refer to Service - Pump (flavor) |
|
| start switches for test procedures. |
|
| See page 15 |
Incorrect mix ratio | 1. No water | Water lines and valves to the dis- |
|
| penser must be open. |
| 2. Needle valve | Refer to Setup - Mix Ratio Adjust- |
|
| ments for adjustment. See page 5 |
| 3. Solenoids | Refer to Service - Solenoids for test |
|
| procedures. See page 17 |
Motor thermal cutout (motor stops | 1. Motor overheat | The thermal switch will reset, but |
running) |
| requires up to 30 minutes of cooling |
|
| time. See NOTE below |
NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time.