ENABLE BrewLOGIC

ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

ENABLE BrewLOGIC

NO DONE YES

Go to

SPRAY OZ/M:

PLACE BREWER IN FINAL LOCATION

CALIBRATE NOW?

NOYES

ACCURACY RISK!!!

OKCAL.

Go to CAL

LP1-LP2

TOO HOT-WILL

COOL TANK NOW

PRESS BREW WHEN CONTAINER READY

COOLING TANK

PLEASE WAIT

The BrewLogic system allows the brewer to be calibrated to high mineral locations and compensate as deposits build up internally. Press YES, then press DONE. Follow the prompts.

Pertains only to software version 1.07 & above!

Select a sturdy, level location.

Brewer must not be bumped during calibration!

Select YES for calibration. Selecting NO warns of accuracy risk

Select CAL. to start calibration procedure. Selecting OK will skip to level probe calibration screen.

Automatically checks to see if tank temperature is between 130°-170°F (54°-76°C)

Verify brew funnel and decanter/airpot/thermal server (depend- ing on which model you have) are in place. Then press the "BREW START" button.

Message will be displayed while dispense is being performed. Tank heaters are turned off and the unit will dispense for ~1 minute to cool tank temperature.