Bunn Axiom manual PROGRAMMING FUNCTIONS - LEVEL 2 cont, SET PASSWORD 0 0 SET LANGUAGE NOYES UNITS

Models: Axiom

1 17
Download 17 pages 40.32 Kb
Page 9
Image 9
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

NOTE: Access to the remaining functions in LEVEL 2 is intended for trained service personnel only. More in depth information can be found in the Axiom Service Manual 39132.0000

SET PASSWORD

0 0 0

SET LANGUAGE

NOYES

UNITS

METRIC DONE ENG

SET TEMP: 200°

(-) DONE (+)

SET READY: 195°

(-) DONE (+)

ENTER ASSET # ?

NOYES

Any 3 digit number may be programmed to prevent unauthor- ized access of LEVEL 2. BE CAREFUL TO USE A CODE YOU WILL

REMEMBER!

Choose between English or Spanish. After selecting "YES", press either ( + ) or ( - ) to select, then choose "YES" again when asked, "ARE YOU SURE?"

Choose between English or Metric units. Display will read:

"CHANGING UNITS WILL CAUSE" "ALL SETUP INFO TO BE LOST" "ARE YOU SURE?" "NO YES". NOTE: If the brewer is set for Metric Units, displays will be different. (ex: Brew oz will become Brew Liters, ° F will be ° C).

Adjusts brew tank temperature.

RANGE: (185 to 205° F) or (85 to 96° C)

This function sets the minimum temperature allowable to start a brew cycle. Range: (2° to 20° F) or (2° to 10° C) below the set temperature. The water must be at the "READY" temperature or higher for the display to indicate "READY TO BREW".

This function allows the you to enter in an optional asset num- ber. This can be useful for tracking the usage or service of an individual machine within a group.