PROBLEM
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check For Bad Connections
Temp Sensor Out Of Range,
Check Wire For Shorts
Equipment will not operate
Water flows into tank continu- ously with power removed from brewer.
TROUBLESHOOTING
PROBABLE CAUSE
1.Water temperature in the tank does not meet the ready temperature.
1.Tank Heater failure.
2.Control Board/Thermistor failure
1.Water shut off to brewer
2.Supply line too small or ob- structed
3.Inlet Solenoid failure
4.Control Board Failure
5.ON/OFF switch is OFF
1.Temperature Sensor Probe wire(s) broken or not making connection
1.Temperature Sensor Probe wire(s) shorted to housing or to each other.
1.No power
2.Incorrect voltage
1.Refill valve
REMEDY
A)Wait for the brewer to heat to the proper temperature.
B)Disable the BREW LOCK- OUT function. Refer to program- ming section for procedure.
Service required
Service required
Check water supply
Replace or repair as needed
Service Required
Service Required
Turn switch ON
Service required
Service required
Verify power cord is plugged into outlet.
Service required
Service required
Page 14 | 41154 041708 |
|