TROUBLESHOOTING (cont.)

PROBLEM

 

 

PROBABLE CAUSE

 

REMEDY

Brewer

is making unusual

1. Solenoids vibrating

 

Service required.

noises.

 

 

 

 

 

 

 

 

 

2. Plumbing lines

 

Plumbing lines should not be

 

 

 

 

 

 

resting on the countertop.

 

 

 

3. Water supply

 

The brewer must be connected

 

 

 

 

 

 

to a cold water line. Water pres-

 

 

 

 

 

 

sure to the brewer must not be

 

 

 

 

 

 

higher than 90 psi (620 kPa).

 

 

 

 

 

 

Install a regulator if necessary

 

 

 

 

 

 

to lower the working pressure

 

 

 

 

 

 

to approximately 50 psi (345

 

 

 

 

 

 

kPa).

 

 

 

4. Tank heaters

 

Service required.

"CHECK

SPRAYHEAD FOR

1. Lime buildup in sprayhead

 

Refer to cleaning section.

LIME" - "CHECK FITTINGS

 

 

 

 

FOR LIME"

2. Lime buildup in brew valve

 

Refer to cleaning section.

 

 

 

3. Lime buildup in brew tank

 

Service required.

"WARNING INACCURATE

1. Lime buildup in sprayhead

 

Refer to cleaning section.

FLOW" - "TOO MUCH LIME

 

 

 

 

PLEASE REPAIR"

2. Lime buildup in brew valve

 

Refer to cleaning section.

 

 

 

3. Lime buildup in brew tank

 

Service required.

"WARNINGVERY LOW FLOW"

1. Lime buildup in sprayhead

 

Refer to cleaning section.

- "PLEASE REPAIR"

 

 

 

 

 

 

 

2. Lime buildup in brew valve

 

Refer to cleaning section.

 

 

 

3. Lime buildup in brew tank

 

Service required.