TROUBLESHOOTING (cont.)
PROBLEM |
|
| PROBABLE CAUSE |
| REMEDY | |
Brewer | is making unusual | 1. Solenoids vibrating |
| Service required. | ||
noises. |
|
|
|
|
|
|
|
|
| 2. Plumbing lines |
| Plumbing lines should not be | |
|
|
|
|
|
| resting on the countertop. |
|
|
| 3. Water supply |
| The brewer must be connected | |
|
|
|
|
|
| to a cold water line. Water pres- |
|
|
|
|
|
| sure to the brewer must not be |
|
|
|
|
|
| higher than 90 psi (620 kPa). |
|
|
|
|
|
| Install a regulator if necessary |
|
|
|
|
|
| to lower the working pressure |
|
|
|
|
|
| to approximately 50 psi (345 |
|
|
|
|
|
| kPa). |
|
|
| 4. Tank heaters |
| Service required. | |
"CHECK | SPRAYHEAD FOR | 1. Lime buildup in sprayhead |
| Refer to cleaning section. | ||
LIME" - "CHECK FITTINGS |
|
|
|
| ||
FOR LIME" | 2. Lime buildup in brew valve |
| Refer to cleaning section. | |||
|
|
| 3. Lime buildup in brew tank |
| Service required. | |
"WARNING INACCURATE | 1. Lime buildup in sprayhead |
| Refer to cleaning section. | |||
FLOW" - "TOO MUCH LIME |
|
|
|
| ||
PLEASE REPAIR" | 2. Lime buildup in brew valve |
| Refer to cleaning section. | |||
|
|
| 3. Lime buildup in brew tank |
| Service required. | |
"WARNINGVERY LOW FLOW" | 1. Lime buildup in sprayhead |
| Refer to cleaning section. | |||
- "PLEASE REPAIR" |
|
|
|
| ||
|
|
| 2. Lime buildup in brew valve |
| Refer to cleaning section. | |
|
|
| 3. Lime buildup in brew tank |
| Service required. |
Page 17 | 41154 041708 |
|