Bunn Axiom manual 25.0, Done, Calibrate Flow ? Noyes Brew Counters ? Noyes, Spray Oz/M

Models: Axiom

1 17
Download 17 pages 40.32 Kb
Page 13
Image 13
25.0

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

SPRAY OZ/M:

25.0

View or enter the actual flow rate coming out of the sprayhead.

This is used to tell the internal controller how fast the water

(-)

DONE

(+)

is flowing. Use the "CALIBRATE FLOW" screen to obtain the

most current flow rate.

Range: (3.0 to 75.0 oz) or (100 to 2200ml)

CALIBRATE FLOW ?

NOYES

BREW COUNTERS ?

NOYES

SERVICE TOOLS ?

NOYES

FACTORY DEFAULTS

NOYES

This function provides a 60 second test mode to capture water from the sprayhead. This measurement will then give you the numbers to enter into the "SPRAY OZ/M: xx" screen above.NOTE: Should be performed after deliming and/or changing sprayhead. (Will not display when "BrewLogic" is enabled)

Tracks the total number of brew cycles completed.There is one reset-able counter, and one life counter that is not reset-able

Allows the testing of individual components and the ability to check the membrane switches for proper function. (Diagnostic tool for troubleshooting purposes only)

Reset ALL of the previously entered brew settings, ad mes- sage, calibrations, etc. Factory-set default values will replace ALL previous settings.

NOTE: Items not affected; Service #, Password, Language, Units, Asset #, Counters and Serial Number.

 

 

INITIAL FACTORY DEFAULT VALUES

 

 

Brew Lockout

NO

 

ENABLE ENERGY SAVER -

NO

BREW

64 OZ

(2.0L)

ENABLE FRESH TIMER -

NO

BREW METER

1

 

ENABLE WARMER OFF -

NO

ENABLE ADS

NO

 

REFILL -

 

155

PASSWORD

0

 

SPRAY

25.0 oz/M (739ml/M)

Language

English

 

Software Version 1.07 & above

Units

English

 

BrewLogic

 

OFF

SET TEMP

200° F

(93° C)

 

 

 

SET READY

195° F

(90° C)

 

 

 

ENTER ASSET # -

 

0

 

 

 

PULSE BREW -

 

DISABLED

 

 

DRIP TIME -

 

0:30

 

 

 

ENABLE CLEAN -

 

NO

Page 13

 

 

 

 

 

 

41154 041708

 

 

 

 

 

Page 13
Image 13