TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE | REMEDY |
Water is not hot (Cont.)
Spitting or excessive steaming
4. Tank Heater Switch
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral
Refer to Service - Tank Heater Switch for testing procedures. See page 37
Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.
2. Control Thermostat | Refer to Service - Control Thermo- |
| stat for testing procedures. See |
| page 18 |
Dripping from dispense tip
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral
Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.
2. Dispense Solenoid Valve | Remove the dispense solenoid valve |
| and clear any obstructions. Rebuild |
| or replace the valve if necessary. See |
| page 34 |
Water flows into tank continuously 1. A) Level Control Board and Probe | Refer to Service - Level Control Board |
- | and Probe for testing procedures. |
| See page 29 |
B) Control Board and Probe - FMD- | Refer to Service - Control Board and |
2 | Probe for testing procedures. See |
| page 19 |
2. Solenoid Valve (Inlet) | Refer to Service - Solenoid Valve |
| (Inlet) for testing procedures. See |
| page 35 |