TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Water is not hot (Cont.)

Spitting or excessive steaming

4. Tank Heater Switch

1. Lime build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral build-up on stain- less steel surfaces can initiate corro- sive reactions resulting in serious leaks.

Refer to Service - Tank Heater Switch for testing procedures. See page 37

Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.

2. Control Thermostat

Refer to Service - Control Thermo-

 

stat for testing procedures. See

 

page 18

Dripping from dispense tip

1. Lime build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral build-up on stain- less steel surfaces can initiate corro- sive reactions resulting in serious leaks.

Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.

2. Dispense Solenoid Valve

Remove the dispense solenoid valve

 

and clear any obstructions. Rebuild

 

or replace the valve if necessary. See

 

page 34

Water flows into tank continuously 1. A) Level Control Board and Probe

Refer to Service - Level Control Board

- FMD-1

and Probe for testing procedures.

 

See page 29

B) Control Board and Probe - FMD-

Refer to Service - Control Board and

2

Probe for testing procedures. See

 

page 19

2. Solenoid Valve (Inlet)

Refer to Service - Solenoid Valve

 

(Inlet) for testing procedures. See

 

page 35