TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
PROBABLE CAUSE | REMEDY |
5. Solenoid Valve (Inlet) | Refer to Service - Solenoid Valve |
| (Inlet) for testing procedures. See |
| page 35 |
6.A) Level Control Board and Probe -
B)Control Board and Probe - FMD-
2
7.A) Auger Drive -
B) Auger Drive -
8.Water Strainer
9.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral
Refer to Service - Level Control Board and Probe for testing procedures. See page 29
Refer to Service - Control Board and Probe for testing procedures. See page 19
Refer to Service - Auger Drive. See page 13
Refer to Service - Auger Drive. See Page 15
(A)Direction of flow arrow must be pointing towards dispenser.
(B)Remove the strainer and check for obstructions. Clear or replace.
Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.
Water is not hot
10. Transformer - | Refer to Service - Transformer for | ||
|
| testing procedures. See page 38 | |
1. | Limit Thermostat | Refer to Service - Limit Thermostat | |
CAUTION - Do not eliminate or by- | for testing procedures. See page 31 | ||
pass limit thermostat. Use only BOM |
| ||
replacement part #29329.1000 |
| ||
2. | Control Thermostat | Refer to Service - Control Thermo- | |
|
| stat for testing procedures. See page | |
3. | Tank Heater | 18 | |
Refer to Service - Tank Heater for | |||
|
| ||
|
| testing procedures. See page 36 |
9 | 29112 051200 |
|