SERVICE (cont.)

SOLENOID VALVE (COLD WATER

OPTIONAL)(FMD-2 ONLY)

J1

12

J1

J2

J4

J3

P1666

FIG. 33 COLD WATER SOLENOID VALVE

Location:

The cold water solenoid valve is located on the left side of the dispenser base just behind the com- ponent bracket.

Test Procedures:

1.Disconnect the dispenser from the power source.

2.Disconnect the white and blue wires from the solenoid valve. With the cold jumper plug in- stalled press the left dispense switch on front of the door.

3.Check the voltage across the white and blue wires with a voltmeter. Connect the dispenser to the power source. The indication must be 120 volts ac for two wire 120 volt models, three wire 120/ 208 and 120/240 volt models.

4.Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #5

If voltage is not present as described, refer to wiring diagram and check dispenser wiring harness.

5.Check for continuity across the solenoid valve coil terminals.

If continuity is present as described, reconnect the white and blue wires to the solenoid.

If continuity is not present as described, replace the solenoid valve.

6.Check the solenoid valve for coil action. Connect the dispenser to the power source. With the cold jumper plug installed press the left dispense switch and listen carefully in the vicinity of the solenoid valve for a “clicking” sound as the magnet attracts.

7.Disconnect the dispenser from the power source.

If the sound is heard as described and water will not pass through the solenoid valve, there may be a block- age in the water line before the solenoid valve or, the solenoid valve may require inspection for wear, and removal of waterborne particles.

If the sound is not heard as described, replace the solenoid valve.

Removal and Replacement:

1.Loosen the two screws securing the component bracket to the dispenser base. Lift the component bracket off of the base and move to the right.

2.Remove the white and blue from the solenoid valve.

3.Turn-off the water supply to the dispenser.

4.Disconnect the water lines to and from the sole- noid valve.

5.Loosen the two #8-32 screws and washers secur- ing the solenoid mounting bracket to the base. Remove solenoid bracket and solenoid valve as an assembly.

6.Remove the two #10-32 screws and lockwashers securing the solenoid valve to the solenoid bracket.

7.Using two #10-32 screws and lockwashers install new solenoid valve on solenoid mounting bracket.

8.Install the solenoid valve and bracket on the dis- penser base and tighten the two #8-32 screws.

9.Securely fasten the water lines to and from the solenoid valve.

10.Refer to Fig. 34 when reconnecting the wires.

BLU to Main Harness

WHI to Main Wiring

Harness

P1215

FIG. 34 COLD WATER SOLENOID TERMINALS

33

29112 101598

 

Page 33
Image 33
Bunn FMD-1 service manual Solenoid Valve Cold Water OPTIONALFMD-2 only, Cold Water Solenoid Valve

FMD-2, FMD-1 specifications

The Bunn FMD-2 is an advanced coffee dispensing machine designed for high-traffic environments, such as cafés, restaurants, and convenience stores. This commercial coffee equipment stands out for its reliability, efficiency, and user-friendly features, making it a preferred choice among coffee retailers.

A standout feature of the FMD-2 is its dual coffee bean hopper system, which allows for the storage and dispensing of two different coffee blends simultaneously. This versatility provides establishments the opportunity to cater to varying customer preferences, whether they prefer a robust espresso or a smooth medium roast. The hoppers can hold a significant amount of coffee beans, ensuring that the machine can keep up with high demand without the need for frequent refilling.

The FMD-2 incorporates state-of-the-art brewing technology, including the ability to brew coffee quickly while preserving the essential flavor characteristics of the beans. Its precision brewing process ensures consistency in taste and quality, which is crucial for customer satisfaction in a commercial setting. The machine is equipped with adjustable brew times and temperatures, allowing operators to fine-tune the brewing process according to specific coffee styles or customer preferences.

Another notable characteristic of the Bunn FMD-2 is its digital interface, which features an intuitive touchscreen display. This modern interface simplifies the operation of the machine, enabling baristas and staff to quickly train and adapt to its functionalities. The display provides real-time feedback on brewing status, maintenance reminders, and settings adjustments, making it easier to ensure optimal performance and reduce downtime.

In addition to its user-friendly design, the Bunn FMD-2 is constructed for durability. Its stainless steel exterior not only enhances its aesthetic appeal but also ensures that it can withstand the rigors of daily use in a bustling environment. The machine is designed with easy maintenance in mind, allowing for straightforward cleaning and servicing to keep it operating at peak performance.

Overall, the Bunn FMD-2 is a versatile, reliable, and innovative coffee dispensing solution that meets the demands of today’s coffee enthusiasts. With its dual hopper system, precision brewing technology, and user-friendly interface, it’s an ideal choice for any establishment looking to elevate their coffee offerings and enhance customer experience.