11. Disconnect the dispenser from the power source.

SERVICE (cont.)

Electronic Controls (cont.)

11. Disconnect the dispenser from the power source.

If voltage was present as described, return the new triac assembly to Bunn-O-Matic for credit. The temperature control of the system is operating properly. If voltage was not present as described, reinstall your existing electronic control assembly and temperature sensor, and proceed to #12

12.Replace the triac assembly.

13.Check the voltage across the tank heater terminals with a voltmeter. Connect the dispenser to the power source. The indication must be 200 to 240 volts ac for 200 to 240 volt models while the red indicator on the circuit board is on or blinking.

14.Disconnect the dispenser from the power source.

If voltage was present as described, the temperature control of the system is operating properly. Return the new electronic control assembly and temperature sensor to Bunn-O-matic for credit.

5.Install the new temperature sensor into the grom- met on the tank lid. Route the wires to the location of the new electronic control assembly.

6.Attach the temperature sensor, overflow tube temperature sensor, and indicator wires to the electronic control assembly.

7.Fasten the new electronic control assembly to its bracket.

8.Reconnect the wires.

9.Review the initial set-up procedures.

BLU to Triac Assy

TAN to Triac Assy

BLU to Triac Assy

TAN to Triac Assy

PNK to Liquid Level Probe

RED to Terminal block

RED to Solenoid

12.Replace the triac assembly. BLK to Overflow Safety Switch

14.Disconnect the dispenser from the power source. GRN to Chassis Ground

WHI/BLU to Solenoid

Electronic Control Removal and Replacement

FIG. 2 WIRING CONNECTIONS

P1992

NOTE - Each electronic control assembly is calibrated to a temperature sensor probe. Both components MUST be replaced as a set.

1.Remove all wires from the electronic control as- sembly terminals.

2.Remove the two 8-32 screws holding the electronic control assembly to the component bracket.

3.Disconnect the temperature sensor, overflow tube temperature sensor, and indicator wires from the left side of the electronic control assembly board.

4.Remove the temperature sensor from the grommet in the tank lid.

WHI & WHI to

 

Temperature Sensor

 

PNK & GRY to

P1

 

Heater Indicator

P2

Refill Indicator

Power Indicator

 

Ready Indicator

 

GRY & GRY

 

to Thermistor

P101

 

P1992

FIG. 3 WIRING CONNECTIONS

13

10889 091599

 