TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Water is cold (cont.) | 3. Tank heater | Refer to Service - Tank heater for |
|
| testing procedures. See page 19. |
| 4. Temperature control | Refer to Service - Electronic con- |
|
| trols for testing procedures. See |
|
| page 12. |
| 5. Dry plug protection | Check connections to Interlock |
|
| board and sheath of tank tempera- |
|
| ture probe. |
Water boils continuously. | 1. Temperature control | Refer to Service - Electronic con- |
|
| trols for testing procedures. See |
|
| page 12. |
| 2. Lime | Inspect the tank assembly for excess |
|
| lime deposits. Delime as required. |
CAUTION - Tanks and tank components should be delimed regularly depending on local water conditions. Exces- sive mineral
Dispenser is making unusual nois- 1. | Solenoid valve |
es. |
|
2. | Plumbing lines |
3. | Water supply |
Ready indicator will not light. (when 1. | Temperature control |
temperature is within 4˚ of its se- |
|
lected setting.) |
|
2. | Ready Indicator LED |
The nut on top of the solenoid valve must be tight or it will vibrate during operation.
Plumbing lines should not be resting on the counter top.
(A)the dispenser must be connected to a cold water line.
(B)Water pressure to the dispenser must not be higher than 90 psi. Install a regulator if necessary to lower the working pressure to ap- proximately 50 psi.
Refer to Service - Electronic con- trols for testing procedures. See page 12.
Replace the indicator LED.