Bunn H10X TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, board and sheath of tank tempera

Models: H10X

1 20
Download 20 pages 6.76 Kb
Page 8
Image 8

TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Water is cold (cont.)

3. Tank heater

Refer to Service - Tank heater for

 

 

testing procedures. See page 19.

 

4. Temperature control

Refer to Service - Electronic con-

 

 

trols for testing procedures. See

 

 

page 12.

 

5. Dry plug protection

Check connections to Interlock

 

 

board and sheath of tank tempera-

 

 

ture probe.

Water boils continuously.

1. Temperature control

Refer to Service - Electronic con-

 

 

trols for testing procedures. See

 

 

page 12.

 

2. Lime build-up

Inspect the tank assembly for excess

 

 

lime deposits. Delime as required.

CAUTION - Tanks and tank components should be delimed regularly depending on local water conditions. Exces- sive mineral build-up on stainless steel surfaces can initiate corrosive reactions resulting in serious leaks.

Dispenser is making unusual nois- 1.

Solenoid valve

es.

 

2.

Plumbing lines

3.

Water supply

Ready indicator will not light. (when 1.

Temperature control

temperature is within 4˚ of its se-

 

lected setting.)

 

2.

Ready Indicator LED

The nut on top of the solenoid valve must be tight or it will vibrate during operation.

Plumbing lines should not be resting on the counter top.

(A)the dispenser must be connected to a cold water line.

(B)Water pressure to the dispenser must not be higher than 90 psi. Install a regulator if necessary to lower the working pressure to ap- proximately 50 psi.

Refer to Service - Electronic con- trols for testing procedures. See page 12.

Replace the indicator LED.

8

10889 072700

 

Page 8
Image 8
Bunn H10X manual TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, board and sheath of tank tempera, Plumbing lines