TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Automatic refill will not operate after | 1. No water | Check plumbing and |
drawing hot water. |
| valves. |
| 2. Water strainer/flow control | (A) Direction of flow arrow must be |
|
| pointing towards dispenser. |
|
| (B) Remove the strainer/flow control |
|
| and check for obstructions. Clear or |
|
| replace. |
| 3. Overflow protection switch | Refer to Service - Overflow protec- |
|
| tion switch for testing procedures. |
|
| See page 16. |
| 4. Liquid level system | Refer to Service - Electronic con- |
|
| trols for testing procedures. See |
|
| page 11. |
| 5. Solenoid valve | Refer to Service - Solenoid valve for |
|
| testing procedures. See page 17. |
| 1. Solenoid valve | Refer to Service - Solenoid valve for |
|
| testing procedures. See page 17. |
Water flows into the tank continu- | 1. Liquid level system | Refer to Service - Electronic con- |
ously. (Dispenser disconnected from |
| trols for testing procedures. See |
power source). |
| page 11. |
Water flows into the tank con- | 1. Overflow protection switch | Refer to Service - Overflow protec- |
tinuously (Dispenser connected to |
| tion switch for testing procedures. |
power source). |
| See page 16. |
Water is cold. | 2. Limit thermostat | Refer to Service - Limit thermostat |
|
| for testing procedures. See page |
|
| 15. |
CAUTION - Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0003.