SERVICE (cont.)

SERVICE (cont.)

Solenoid Valve (cont.)

5.Lift out the solenoid valve.

6.Remove the two 10-32 slotted-head screws holding the solenoid valve to its mounting bracket.

7.Securely install the new solenoid valve to its mount- ing bracket. The direction of flow arrow must be pointing towards the tank lid.

8.Attach the solenoid valve and mounting bracket to the component bracket.

9.Securely fasten the water lines to and from the solenoid valve.

10.Reconnect the wires, FIG. 10.

WHI/BLU to Electronic

Contol #1

RED to Terminal Block

RED to Electronic Control #5

P1779

FIG. 10 SOLENOID VALVE WIRING