SERVICE (cont.)
Solenoid Valve (cont.)
5.Lift out the solenoid valve.
6.Remove the two
7.Securely install the new solenoid valve to its mount- ing bracket. The direction of flow arrow must be pointing towards the tank lid.
8.Attach the solenoid valve and mounting bracket to the component bracket.
9.Securely fasten the water lines to and from the solenoid valve.
10.Reconnect the wires, FIG. 10.
WHI/BLU to Electronic
Contol #1
RED to Terminal Block
RED to Electronic Control #5
P1779
FIG. 10 SOLENOID VALVE WIRING
18 | 10889 091599 |
|