Bunn H5E H5X service manual SERVICE cont Electronic Controls cont, H5E THERMOSTAT PROBLEM Boils

Models: H5E H5X

1 22
Download 22 pages 14.85 Kb
Page 12
Image 12
H5X THERMOSTAT

SERVICE (cont.)

Electronic Controls (cont.)

7.Reconnect the pink wire to terminal 5 of the elec- tronic control assembly.

8.Loosen the compression fitting, remove the probe from the tank lid, and inspect it for mineral depos- its. Replace it if necessary. Keep the exposed ends of the probe away from any metal surface of the dispenser.

9.Check the voltage across terminals 1 & 4 of the electronic control assembly with a voltmeter. Con- nect the dispenser to the power source. The indi- cation must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models after a delay of approximately 5 seconds.

10.Touch the screw head end of the probe to the dis- penser housing. The indication must be 0.

11.Move the probe away from the dispenser housing. The indication must again be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models after a delay of approximately 5 seconds.

12.Disconnect the dispenser from the power source.

Temperature Control Flow Charts (cont.)

H5X THERMOSTAT

PROBLEM: Boils Excessively - Fills Cup

If voltage was present as described, reinstall the probe, the sensing function of the system is operating prop- erly.

If voltage was not present as described, check the pink probe wire and the green ground wire for continuity and/or replace the probe.

Temperature Control Test Procedure

1.Disconnect the dispenser from the power source.

2.Check the voltage across terminals 3 & 4 of the electronic control circuit board with a voltmeter. Connect the dispenser to the power source.The in- dication must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models.

3.Disconnect the dispenser from the power source.

If voltage was present as described, proceed to #4.

If voltage was not present as described, refer to the Wiring Diagram and check the dispenser wiring har- ness.

4.Connect the dispenser to the power source and place the tank heater switch in the “ON” position.

5.Observe the red indicator on the electronic control circuit board.

6.Disconnect the dispenser from the power source.

H5E THERMOSTAT

PROBLEM: Boils

Drain cup

Retry

Red Light On While

Boiling

?

No

Yes

Replace Steam Sensor

Drain cup

Retry

Red Light On While

Yes

 

Boiling

 

?

 

No

 

Replace Control Assembly

Disconnect Blue Wire From

Control Board Pin 7

Retry

Still Boiling

?

No

Finished

Yes

Replace Control Assembly

Disconnect Blue Wire From

Control Board Pin 7

Retry

Still Boiling

?

No

Yes

Replace Triac Assembly

Check For Split

Tank Heater

Still Boiling

Yes

?

 

No

 

Replace Triac Assembly

Check For Split

Tank Heater

Replace Control Assembly

Replace Control Assembly

12

10420 011599

 

Page 12
Image 12
Bunn H5E H5X service manual SERVICE cont Electronic Controls cont, H5X THERMOSTAT PROBLEM Boils Excessively - Fills Cup