SERVICE
This section provides procedures for testing and replacing various major components used in this dis- penser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.
Component Access
WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replace- ment of any component.
WARNING
Fill | ! |
| ER SOUNRECVEERODUCT |
coThis |
mplyequi |
ofAatdnhdmeittFnhhioeseotwrFdBiaotutahoiolnprdtddshimnSeIDegnertBnrueOtvairigfscfnsiieAacctitodiSaPolmlbasnuienanmialiti,nsnabtItdisrinntoacaCgtn.liloo(CeMdnBdoea(OdtnoeCuoAalf) |
FDA). |
P1770
The check valve, electronic control assembly, safety overflow switch, solenoid valve, overflow tube tem- perature sensor and terminal block are located at the rear of the dispenser. Access is gained by removing the upper and lower rear panels. The upper is attached with six
Fill | ! |
ttUohseperowmwaotesertrattaoWAnrkcbefRNINGor | |
| SOUREVERCE ODUCT |
| coThis |
| mply equ |
| ofAathdnmdeinthFothiseeotrawFdBiouthatooildipnrdthdsminSeInDegerBnrteuOtviagrnsisfficceicAattodiaSPiomblsalunienanmaitaliis,ndnbtiInstainocCgn.lloCe(BddoeOdtoe of |
| tratioMnanCAual) |
| (FDA). |
P1770
The limit thermostat, liquid level probe, tank heater, and temperature sensor are located at the top of the dispenser. Access is gained by removing the top lid, attached with three
The triac assembly is located beneath the tank. Access is gained by removing four feet and the bottom panel attached with seven
NOTE - Completely drain the tank before tipping the dispenser.
WARNING – Inspection, testing, and repair of electrical equipment should be performed only by qualified ser- vice personnel. Disconnect the dispenser from the power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source.
Electronic Controls | 10 |
Limit Thermostat | 16 |
Safety Overflow Switch | 17 |
Solenoid Valve | 18 |
Tank Heater | 19 |
WARNING
W
P1770
Electronic Control Assembly Troubleshooting: Check these items first
•Is circuit board
•Is circuit board wet due to misaligned overflow tube?
•Is water in overflow cup activating float switch?
•Is overflow cup not making good contact with tank?
•Is dispenser being operated with panels removed?
9 | 10420 011599 |
|