Bunn H5E H5X service manual SERVICE cont Tank Heater, BLU to Triac Assy, Thermostat

Models: H5E H5X

1 22
Download 22 pages 14.85 Kb
Page 19
Image 19
SERVICE (cont.)

SERVICE (cont.)

Tank Heater

Location:

The tank heater is located in the tank lid.

DO N

!

ON N

P1772

U

OT

Tu

 

 

ntil

 

 

 

 

Wa rn

 

 

A Hot

terCAUTIOn h

N

 

utomatiWater Somes FeTank

 

FIG. 12 TANK HEATER

 

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Check the voltage across the terminals of the tank heater with a voltmeter. Connect the dispenser to the power source. The indication must be:

a.) 100 to 120 volts ac for 100 to 120 volt models or

b.) 200 to 240 volts ac for 200 to 240 volt models.

3.Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #4.

If voltage is not present as described, replace the tank heater.

4.Remove the tank heater from the tank lid and in- spect it for cracks in the sheath.

If the sheath shows no sign of damage, proceed to #5. If the sheath is damaged, replace the tank heater.

5.Check for continuity across the tank heater termi- nals.

If continuity is present as described, reinstall the tank heater. The tank heater is operating properly.

If continuity is not present as described, replace the tank heater.

Removal and Replacement:

1.Remove the wires to the tank heater.

2.Remove the 8-32 nuts from the tank heater flange.

3.Remove the tank heater.

4.Inspect the tank heater gasket and replace if nec- essary.

5.Securely install the new tank heater. Be certain of a watertight seal.

6.Reconnect the wires, FIG. 13.

BLU to Triac Assy

BLK to Limit

 

Thermostat

P1780

FIG. 13 TANK HEATER WIRING

19

10420 011599

 

Page 19
Image 19
Bunn H5E H5X service manual SERVICE cont Tank Heater, BLU to Triac Assy, Thermostat