ADJUSTMENT & OPTIONAL SETTINGS

ADJUSTMENT & OPTIONAL SETTINGS

Water Flow Testing and Adjustment

1.Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the ap- propriate dispense nozzle. Place the Program switch in the ON position.

2.Press and release the desired “Product Dispense Switch” three times.

(On Portion Control models, use the plus/stop switches)

3. The selected position will dispense water (no concentrate) only for 3 seconds.

4. Measure the water dispensed.

 

 

 

5. Adjust the water flow rate Fig 17, (clockwise to increase flow rate;

 

P3586

counterclockwise to decrease flow rate) to the corresponding product

 

FIG 17 Adjusting Water Flow

mix ratio as follows:

 

 

 

 

Using 1/4" allen wrench

 

 

 

 

 

 

 

Mix Ratio

Adjust water flow rate to:

Product

Brix %

(water + concentrate)

 

 

 

 

2+1

*3.75 fl. oz (111 ml)

Prune Juice

16.0%

 

per 3-second test

Other

 

*

4+1

 

Orange Juice

11.8%

 

Pineapple Juice

12.8%

 

*4.0 fl. oz (118 ml)

Cranberry Fruit Cocktail

14.0%

 

Grapefruit Juice

10.6%

 

5+1

per 3-second test

Lemonade

 

 

Apple Juice

12.0%

 

 

Fruit Punch

 

 

 

Grape Juice

13.0%

3+1 through 7+1

 

Other

 

*

Above 7+1

*4.0 fl. oz (118 ml)

Other

 

*

 

per 3-second test

 

 

 

High Viscosity Juice

2.25 - 3.0 fl. oz (66.5 - 89 ml)

As Required

-

 

per 3-second test

 

 

 

*Maximum flow rate may be less depending on the water pressure supply at each location.

Note: Information for specific products listed in this table is to be used for reference only. Consult the product label for exact mix ratio and/or brix %. See product label for target brix %.

6.Repeat steps 1 through 5 as necessary until the correct water flow rate is achieved.

7.Repeat steps 1 through 5 for the remaining dispense positions.

8.Place the Program switch back into the OFF position.

Pump Speed Adjustment

1.Disconnect the dispenser from the power source.

2.Remove the drip tray.

3.Remove the two screws securing the splash panel and remove the splash panel

4.Locate the adjustment knobs on the circuit board.

5.Turn the adjustment knobs clockwise to increase speed and counterclockwise to decrease speed.

6.The knob positions directly correspond to dispense station locations.

NOTE: Some 2S models have 4 adjustment knobs on the circuit board. For these models use the two left most knobs to make pump speed adjustments. Left most being station #1 (left side dispense) and left center being station #2 (right side dispense).

7. Reinstall the splash panel and drip tray and reconnect the dispenser to the power source.