MOVING THE WEIGHT SYSTEM
To move the weight system, step on the levers on the Locking Casters (76) to unlock the wheels. Move the weight system to the new location. Relock the wheels on the Locking Casters.
CHANGING THE WEIGHT SETTING
To change the setting of the weight stack, insert the Weight Pin (28) under the desired Weight (27). Insert the Weight Pin so that the bent end touches the weight stack. Turn the bent end down.
Note: Due to the cables and pulleys, the amount of resistance at each exercise station may vary from the weight setting. Use the WEIGHT RESISTANCE CHART on page 17 to find the approximate amount of resistance.
ADJUSTING THE CABLE
Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is slack in the cable before resistance is felt, the cables should be tightened.
To tighten the Press Arm Cable (66), remove the M10 x 50mm Bolt (96) from the Weight Tube (16). Reattach the 3 1/2" Pulley (43), the Cable Trap (47), and the two Finger Guards (48) to a lower hole in the Weight Tube with the Bolt and an M10 Nylon Locknut (108). Make sure that the Cable Trap is oriented to hold the Press Arm Cable (66) in the groove of the Pulley. To loosen the Cable, attach the Pulley to a higher hole in the Weight Tube.
| Lever | |
| 76 | |
| 27 | |
| 28 | |
| 66 | |
| 48 | |
48 | 43 | |
47 | ||
| ||
16 | 108 | |
96 |
| |
16 |
|