Page 10
TROUBLESHOOTING (cont.)
Problem
Brew cycle will not start. (cont.)
Water flows into fill basin continu-
ously (On/Off brew station warmer
switch “OFF”).
Water flows into fill basin continu-
ously (On/Off brew station warmer
switch “ON”).
Water is not hot.
Decanter warmer is not hot.
Probable Cause
4. On/Off Brew Station Warmer
Switch
5. Start Switch
6. Relay
7. Solenoid Valve
1. Solenoid Valve
1. Start Switch
1. Limit Thermostat
CAUTION
Do not eliminate or bypass limit
thermostat. Use only B.O.M. replace-
ment part #29329.1000
2. Control Thermostat
3. Tank Heater
1. Warmer Switches
2. Decanter Warmers
Remedy
Refer to Service - On/Off Brew
Station Warmer Switch for testing
procedures. See page 15.
Refer to Service - Start Switch for
testing procedures. See page 17.
Refer to Service - Relay for testing
procedures. See page 21.
Refer to Service - Solenoid Valve for
testing procedures. See page 20.
Refer to Service - Solenoid Valve for
testing procedures. See page 20.
Refer to Service - Start Switch for
testing procedures. See page 17.
Refer to Service - Limit Thermostat
for testing procedures. See page
19.
Refer to Service - Control Thermo-
stat for testing procedures. See
page 13.
Refer to Service - Tank Heater for
testing procedures. See page 22.
(A) The Warmer Switch(es) must be
in the “ON” position for the warmer
to operate.
(B) Refer to Service - Warmer
Switch(es) for testing procedures.
See pages 15 & 16.
Refer to Service - Warmers for test-
ing procedures. See page 14.
32430 070700