Bunn T6, T3A TROUBLESHOOTING cont PROBLEM, Spitting or excessive steaming, Probable Cause, Remedy

Models: T6 T6A T3A

1 30
Download 30 pages 3.94 Kb
Page 11
Image 11

TROUBLESHOOTING (cont.)

PROBLEM

Spitting or excessive steaming

PROBABLE CAUSE

1. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

REMEDY

Inspect tank assembly for excessive lime deposits. Delime as required.

2. Control Thermostat

Drip-out time too long

1. Funnel Tip

Refer to Service - Control Thermo- stat for testing procedures. See page 20

The brew funnel should be cleaned thoroughly before each brew cycle to lessen the chance of tea leaf par- ticles clogging the drip-out tip.

Dripping from sprayhead

1.

Syphon System

 

2.

Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

The brewer must be level or slightly lower in front to syphon properly.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

3. Brew Solenoid Valve

Water flows into tank continuously

1. Brew Timer

(ON/OFF or Slector Switch "ON")

 

Water flows into tank continuously

1. Brew Solenoid Valve

(ON/OFF or Selector Switch "OFF")

 

Refer to Service - Brew Solenoid Valve for testing procedures. See page 15

Refer to Service - Brew Timer for testing procedures. See page 17 or 18

Refer to Service - Brew Solenoid Valve for testing procedures. See page 15

Page 11

10145

072600

 

 

Page 11
Image 11
Bunn T3A, T6A service manual TROUBLESHOOTING cont PROBLEM, Spitting or excessive steaming, Probable Cause, Remedy