Bunn T3A TROUBLESHOOTING cont PROBLEM, Beverage overflows dispenser Weak beverage, Probable Cause

Models: T6 T6A T3A

1 30
Download 30 pages 3.94 Kb
Page 12
Image 12

TROUBLESHOOTING (cont.)

PROBLEM

Beverage overflows dispenser

Weak beverage

PROBABLE CAUSE

1.Dispenser

2.Brew Timer

3.Brew Solenoid Valve

4.Dilution Timer

5.Dilution Solenoid Valve

1.Filter Type

2.Tea

3.Sprayhead

4.Funnel Loading

5.Water Temperature

REMEDY

The dispenser must be completely empty before starting a brew cycle.

Refer to Service - Brew Timer for testing procedures. See page 17 or 18

Remove the Brew Solenoid Valve and clean any obstruction. Rebuild or replace the valve if necessary. See page 15

Refer to Service - Dilution Timer for testing procedures. See page 22

Refer to Service - Dilution Solenoid Valve for testing procedures. See page 21

BUNN® paper filters must be used for proper extraction.

A sufficient quantity of fresh, loose tea leaves should be used for proper extraction.

Asix-hole stainless steel spray- head must be used for proper ex- traction.

The BUNN® paper filter must be centered in the funnel and the bed of tea leaves leveled by gentle shak- ing.

Place an empty funnel into the fun- nel rails on the brewer. Initiate a brew cycle and check the water temperature immediately below the sprayhead with a thermometer. The reading should not be less than 200°F(93°C). Adjust the control thermostat to increase the water temperature. Replace if necessary.