TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Dilution cycle will not start (cont.) | 4. Dilution Solenoid Valve | Refer to Service - Dilution Solenoid |
|
| Valve for testing procedures. See |
|
| page 21 |
Inconsistent beverage level in dis- penser
1. Internal Flow Control (.195 GPM)
2.Syphon System
3.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
(A)Direction of flow arrow must be pointing towards the brewer.
(B)Remove the flow control and check for obstruction. Clear or re- place.
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
| 4. | Water Pressure | The water pressure to the brewer |
|
|
| must be at least 20 psi (138 kPa). |
Consistently high or low beverage | 1. | Brew Timer/Dilution Timer | With the ON/OFF switch "ON" adjust |
level in the dispenser |
|
| the brew timer to achieve the rec- |
|
|
| ommended 76 oz of concentrate |
|
|
| then the dilution timer to achieve a |
|
|
| total of 396 oz for each |
|
|
| lon brew cycle. |
| 2. | External Strainer/Flow Control | (A) Direction of flow arrow must be |
| (.750GPM) | pointing towards brewer. |
(B) Remove the strainer/flow con- trol and check for obstructions. Clear or replace.
Page 10 | 10145 | 072600 |
|
|