Bunn TNTF-3, TNT-3 manual Probable Cause, TROUBLESHOOTING cont, Problem, Remedy

Models: TNT-3 TNTF-3

1 30
Download 30 pages 2.62 Kb
Page 10
Image 10

TROUBLESHOOTING (cont.)

 

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Dilution (Iced Tea) cycle will not

2. Start Switch

Refer to Service - Start Switch for

start (cont.)

 

 

testing procedures. See page 27

 

3.

Brew Timer (Iced Tea)

Refer to Service- Brew Timer (Iced

 

 

 

Tea) for testing procedures. See

 

 

 

page 20 or 21

 

4.

Brew Solenoid Valve (Iced Tea)

Refer to Service - Brew Solenoid

 

 

 

Valve (Iced Tea) for testing proce-

 

 

 

dures. See page 16

 

5.

Dilution Solenoid Valve

Refer to Service - Dilution Solenoid

 

 

 

Valve for testing procedures. See

 

 

 

page 24

Inconsistent beverage level in

1. Internal Flow Control (.222 GPM)

dispenser (Hot Tea)

 

2. Syphon System

3. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

(A)Direction of flow arrow must be pointing towards the brewer.

(B)Remove the flow control and check for obstruction. Clear or re- place.

The brewer must be level or slightly lower in front to syphon properly.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

 

4.

Water Pressure

The water pressure to the brewer

 

 

 

must be at least 20 psi.

Consistently high or low beverage

1.

Brew Timer

With the ICED/OFF/HOT switch in

level in the dispenser

 

 

the "ICED" position adjust the needle

 

 

 

valve to achieve the recommended

 

 

 

76 oz of concentrate then the timer

to achieve a total of 396 oz for each three-gallon brew cycle.

Page 10

28201 081500

Page 10
Image 10
Bunn TNTF-3, TNT-3 manual Probable Cause, TROUBLESHOOTING cont, Problem, Remedy